Emerson PRF 1080 User Manual

Liebert, Pss™ surge suppressor, Caution

Advertising
background image

Liebert

®

PSS™ Surge Suppressor

Quick-Start Guide - Models PRF 1080, NET 1080T

I

MPORTANT

S

AFETY

I

NSTRUCTIONS

SAVE THESE INSTRUCTIONS

This manual contains important instructions that should be

followed during installation and maintenance of the Liebert

PSS surge suppressor.
• Intended for installation in a controlled environment.
• Maximum ambient temperature 104°F (40°C).

• Do not connect equipment that may overload the surge

suppressor or demand half-wave rectification, such as a

laser printer.

• Connect the surge suppressor only to an earthed /

grounded outlet that meets national and local electrical

safety guidelines.

• Locate the surge suppressor near a wall outlet. Do not

use an extension cord between the surge suppressor and
the outlet.

• The Liebert PSS has been designed for small office/home

office use only; it is NOT recommended for use in life-
support applications.

• In the event of an emergency, press the OFF button and

disconnect the power cord from the AC power supply to
properly disable the surge suppressor.

• Do not attach power strips or other surge suppressors to

the Liebert PSS surge suppressor.

• Do not attempt to service any parts inside the surge sup-

pressor. Failure to adhere to this could cause personal
injury or equipment malfunction and void the warranty.

• For technical support:

• Visit

www.liebert.com

or

• Send an e-mail to

[email protected]

.

S

ETUP

Congratulations on purchasing the Liebert PSS Surge

Suppressor.
The Liebert PSS is designed to protect 120 Volt electronic

equipment. The surge suppressor is capable of carrying up to

15A current.
Follow these instructions to ensure that your Liebert PSS

surge suppressor is properly installed and functioning.

Step 1 Connect AC Equipment to the Liebert PSS

(Models PRF 1080 and NET 1080T)

• Plug the surge suppressor into a grounded outlet only.
• Plug the cords from your computer, home entertainment or

other electrical equipment into the surge suppressor’s
receptacles.

• For large transformer blocks, use one of the three

dedicated outlets on your surge suppressor.

Step 2 Connect Network Electronics

(Model NET 1080T only)

• Disconnect the end of your network line at the wall or

modem end.

• Connect it to one of the OUTPUT connections on the

NET 1080T.

• Connect a patch cord to the INPUT connection on the

NET 1080T.

• Connect the other end of the patch cord to the original

wall or modem outlet.

Step 3 Apply Power to the Liebert PSS

(Models PRF 1080 and NET 1080T)

• Turn the power switch to the ON position.

!

CAUTION

To reduce the risk of fire, connect only to a circuit
provided with 15 amperes maximum branch circuit
overcurrent protection in accordance with the
national code, ANSI/NFPA 70.

!

CAUTION

This protector is intended for indoor use on
communication loop circuits, which have been
isolated from the Public Switched Telephone
Network. The communication loop circuits shall not
be exposed to accidental contact with electrical light
and/or power conductors.

Advertising
This manual is related to the following products: