Eaton 9135 ups – Eaton 9135 User Manual

Page 4

Advertising
background image

SINGAPORE

Tel : +65 6825 1684

Fax : +65 6825 1689

[email protected]

INDONESIA

Tel : +62 21 522 6181

Fax : +62 21 522 6182

MALAYSIA

Tel : +603 7804 3618

Fax : +603 7803 6193

THAILAND

Tel : +662 946 6843

Fax : +662 519 0574

VIETNAM

Tel : +84 4 3936 5303

Fax : +84 4 3936 5307

Eaton is the trade name, trademark, and/

or service mark of Eaton Corporation or its

subsidiaries and affi liates.

® 2008 Eaton Corporation
All Rights Reserved
Printed in Singapore
July 2010

General

User interface

Graphical LCD with blue backlight and text in
English, French, German, Portuguese, Italian and
Spanish

LEDs

Four status-indicating LEDs

Topology

Double-conversion

Diagnostics

Full system self-test

UPS bypass

Automatic bypass

Dimensions

See models selection guide

Rail kit

Included with all units

Electrical Input

Nominal voltage

230V
220V-240V
user selectable

Voltage range

156–280 Vac (output PF 0.7)

Power draw of UPS
(full load)

6000VA: 26A @230V

Recommended input-
breaker rating

35A

Frequency

50/60 Hz autoselect

Frequency range

40–70 Hz

Electrical Output

Power factor

0.7

On utility voltage

±2% of nominal regulation

On battery voltage

±2% of nominal regulation

Efficiency

>97% in high-efficiency mode; 91% in normal mode

Frequency regulation

±3% Hz online

Load crest factor

3 to 1

Battery

Internal battery type

5.5Ah, sealed, lead-acid; maintenance free

Externa battery
modules

Up to four per 9135, rail kits included for rack
mounting

EBM battery type

5.5 Ah, sealed, lead-acid; maintenance free

Battery runtime

Four (4) minutes with internal batteries @100% load
(0.7 PF)

For additional details, see battery runtime chart

Battery recharge
time

Six (6) hours to recover 90 percent of nominal backup
time after 100 percent RCD load discharge

Battery replacement

Hot-swappable internal and external batteries

Start-on-battery

Allows start of UPS without utility input

Communications

Serial port

RS-232 standard, RS-232 cable provided

USB port

HID standard, for communicating with Windows XP/
Vista

Relay output

DB-9 Dry Contact-common alarm standard

Software

Intelligent Power Manager (IPM) and IPP

Optional

communication

cards

ConnectUPS-MS Network Management Card for direct
control and monitoring in SNMP-based ne works
ConnectUPS-MS Card with ModBus RTU interface
Serial Management Card-MS for integration to indus-
trial environment and building management systems,
remote shutdown for IBM AS/400 systems

Environmental

Safety markings

CE, GS

EMC

IEC/EN 62 040-2 class A

Audible noise

Max 46 dB

Ambient operating

0˚C to +40˚C

Storage temperature

-20˚C to +40˚C with batteries and
-25˚C to +55˚C without batteries

Relative humidity

5–90% non-condensing

In the interests of continual product improvement all specifications are subject to change without notice.

Eaton 9135 UPS

Product Focus

TECHNICAL SPECIFICATIONS

Heat Dissipation (BTUs/hr)

Operating mode

Efficiency

5 kVA

6 kVA

Normal

91%

1150

1350

Battery

86%

1650

1960

High efficiency

97%

370

450

Advertising