Accessories, Trouble shooting, How to order repair parts – Emerson CF2000PW02 User Manual

Page 8: Warning

Advertising
background image

Accessories

1. Ceiling Fan Light Kits (see store or catalog).

2. Downrod Extension Kits (see store or catalog).

3. Ceiling Fan Controls (see store or catalog).

Trouble Shooting

TROUBLE

PROBABLE CAUSE

SUGGESTED REMEDY

1. Fan will not start.

1. Fuse or circuit breaker blown.

1. Check main and branch circuit fuses or circuit

breakers.

WARNING:

Make sure main power is turned off.

2. Loose power line connections to the fan, or loose

2. Check line wire connections to fan and switch

switch wire connections in the switch housing.

wire connections in the switch housing.

2. Fan sounds noisy.

1. Blades not attached to fan.

1. Attach blades to fan before operating.

2. Loose screws in motor housing.

2. Check to make sure all screws in motor housing

are snug (not over-tight).

3. Screws securing fan blade flanges to motor hub

3. Check to make sure the screws which attach

are loose.

the fan flanges to the motor hub are tight.

WARNING:

Make sure main power is turned off.

4. Wire connectors inside switch housing rattling.

4. Check to make sure wire connectors in

switch housing are not rattling against each
other or against the interior wall of the switch
housing.

5

Screws holding blades to flanges are loose.

5. Tighten screws securely.

3. Fan wobbles

1. Setscrew in motor coupling is loose.

1. Raise motor cover and tighten setscrew securely.

excessively.

2. Setscrew in hanger ball/downrod assembly is

2. Tighten the setscrew in the hanger ball/downrod

loose.

assembly.

3. Screws securing fan blade flanges to motor hub

3. Check to be sure screws which attach the fan blade

are loose.

flanges to the motor hub are tight.

4. Fan blade flanges not seated properly.

4. Check to be sure the fan blade flanges seat firmly and

uniformly to the surface of the motor hub. If flanges are
seated incorrectly, loosen the flange screws and
retighten according to step 3 in the section “Installing
Fan Blades”.

5. Hanger bracket and/or ceiling outlet box is not

5. Tighten the hanger bracket screws to the outlet box,

securely fastened.

and/or secure outlet box.

6. Fan blades out of balance.

6. Interchanging an adjacent (side-by-side) blade pair can

redistribute the weight and result in smoother operation.
Or use supplied balancing kit to balance blades.

8

Before discarding packaging material, be certain

all parts have been removed.

HOW TO ORDER REPAIR PARTS

WHEN ORDERING REPAIR PARTS, ALWAYS GIVE
THE FOLLOWING INFORMATION:

• PART NUMBER
• PART DESCRIPTION
• NAME OF ITEM
• MODEL NUMBER

For repair parts, phone 1-800-654-3545.

WARNING:

FOR YOUR OWN SAFETY TURN OFF POWER AT FUSE BOX OR CIRCUIT BREAKER

BEFORE TROUBLE SHOOTING YOUR FAN.

!

!

!

This product is designed to use only those parts
supplied with this product and/or any accessories
designated specifically for use with this product by
Emerson. Substitution of parts or accessories not
designated for use with this product by Emerson
could result in personal injury or property damage.

The use of any other control not specifically
approved for this fan could result in fire, shock and
personal injury.

WARNING

!

WARNING

!

Advertising