6.4.3 E

LECTRIC AND PROTECTION SYSTEM

In the electric start models:

The electric system and the electronic card
are protected by a fuse. When it blows the
machine stops, so in this case:

1. tighten the two screws (1) that fasten the

box (2) containing the card, and hold up
the lower part to prevent it from falling;

2. remove the lid (3) and pull out the card

(4) slightly;

3. replace the fuse (5) with another one of

6.3 A (delayed).

4. always put the lid (3) back on and refit

the box (2) in its correct position.

A blown fuse must

always be replaced by one of the same type and ampere rating, and never
with one of another rating.

If you cannot find out why the fuse has blown, consult a Licensed Service
Centre.

In the manual start models:

The electric system and the card are not protected by any fuses. If the safety
system fails to work properly or there are engine problems due to the electric
system, contact a Licensed Service Centre.