4.4.2.1 LENS
1. When the SETUP menu is displayed on the screen, please direct the arrow to point

to “LENS” by using the UP and DOWN buttons. Press the SET button to adjust
IRIS level (the higher is brighter). In most cases, you don’t need to adjust this,
since Lens is Auto Iris supported.




2. Please press SET button for saving setting and return to the previous menu.

4.4.2.2 SHUTTER
1. When the SETUP menu is displayed on the screen, please direct the arrow to point

to “SHUTTER” by using the DOWN button.

2. Select the shutter mode by pressing the LEFT or RIGHT button. Three modes are

available: FLK, ESC and Manual.

Ö

FLK: Please select “FLK” mode when flickering occurs on the screen, which

is caused by an irregular balance between illumination and frequency. NTSC
model: 1/100, PAL model: 1/120.




SETUP

> LENS DC

<┘

SHUTTER ___
WHITE BAL. ATW

BACKLIGHT OFF
AGC MIDDLE
DNR LOW
SENS-UP AUTO

<┘

SPECIAL

<┘

EXIT

LENS

> LEVEL |+++++++++| 20

Note:

Since DC lens is a built-in lens for EDN850H camera, shutter does not support ESC and

Manual functions. ESC and Manual are reserved functions, please do not select these

two options in normal situation.

Note:

Since DC lens is a built-in lens for EDN850H camera, it does not support Manual lens,

please do not select lens as Manual mode, it disables sens-up and may cause malfunction

of lens.