Performance/electrical data – Heatcraft Refrigeration Products CH-B-01 User Manual

Page 9

Advertising
background image

9

Model RAMK
Reverse Air Flow Mullion Reach In Unit Cooler

APPLICATION

The model RAMK is ideal for under-counter reach-in
refrigerators, under-counter drawer type refrigerators and
salad bars. The unit is suitable for mounting behind a mullion
or on a wall. An up flow air pattern is used with air drawn in
at the bottom and discharged out the top. This provides
optimum temperature for drop in trays on salad bars or prep
tables. It also keep drawer stored product in premium
condition.
An adjustable and detachable air deflector/splash protector is
included. The deflector can be adjusted to direct the air up
and out at a 45-degree angle. This feature provides excellent
air distribution over drop in trays or containers. Food in the
trays and containers stays colder, lasts longer, and retains the
desired appearance. The deflector can be adjusted to
distribute air out both sides when used as a mullion unit.
EXCLUSIVE CORROSION-RESISTANT COATING IS STANDARD
The finned coil is protected by a special dip coating that is
baked on to prevent corrosion of the coil by acids that are
present in salad dressings, spiced meats and other food
products.

FEATURES

• Textured aluminum cabinet.
• PVC coated fan guard.
• Stainless steel hardware.
• Coils have full collar aluminum fins on expanded copper

tubes.

• Refrigerant connection knock-outs provided on both ends of

unit.

• Expansion valve mounts inside the unit.
• Motors are thermally protected and permanently lubricated.
• Internal junction box for electrical connection.
• Adjustable air deflector included provides different air

patterns. Air can be directed where its needed.

• UL listed for the United States and Canada; UL classified to

NSF standards.

• Corrosion-resistant coated coil for optimum protection in

corrosive environments.

Performance/Electrical Data

MOTOR DATA

APPROX.

MODEL BTUH

115/1/60

208-230/1/60 CONNECTIONS (IN.) SHIPPING

KMK

10

°

F TD CFM QTY TOTAL FLA TOTAL FLA

INLET SUCTION DRAIN WT. (LBS.)

13

1300

180

2

1.6

0.8

1/2FN 3/8OD 5/8OD

19

17

1700

170

2

1.6

0.8

1/2FN 3/8OD 5/8OD

20

23

2300

255

3

2.4

1.2

1/2FN 3/8OD 5/8OD

28

DIMENSIONAL DATA

MODEL

DIMENSIONS (INCHES)

RAMK

H

L

M

W

X

Y

Z

13

17

3

/

4

16

7

/

8

9

15

5

/

8

2

3

/

4

5

1

/

2

6

15

/

16

17

19

3

/

4

16

7

/

8

10

15

5

/

8

2

3

/

4

6

1

/

2

7

15

/

16

23

19

3

/

4

23

1

/

4

10

22

2

5

/

16

6

1

/

2

7

15

/

16

RAM K 13 A E

Vintage

A = 115/1/60

B = 208-230/1/60

RAM = Reverse

Air Flow

Mullion

Unit Cooler

K = Coated

Coil

Size

NOMENCLATURE

Advertising