Installation instructions – Hotpoint EG52 User Manual

Page 20

Advertising
background image

TECHNICAL DATA

DIMENSIONS

Height

900 - 915mm

Width

600mm

Depth

595mm (excluding door handles)

GENERAL

Gas connection

Rp

1

/

2

(

1

/

2

” BSP female)

Gas Supply

G20 at 20 mbar

Pressure test point

Grill injector

Gas rate adjustment

None

Aeration adjustment

None

Electrical connection

Flexible cord fitted with a 3 pin 13 amp plug
230/240V a.c. 50Hz. 13A fuse.

Oven Heat Input

2.5kW

20

INSTALLATION INSTRUCTIONS

HEAT INPUT

BURNER

3.8 kW

GRILL

3.0 kW

HOTPLATE
Front left and rear right

1.8 kW

HOTPLATE
Front right and rear left

INJECTOR

150

134

109