3

598-1324-01

SPECIFICATIONS

Range . . . . . . . . . . . . . Up to 50 ft. (15.2 m); [varies with

surrounding temperature]

Sensing Angle . . . . . . . Up to 110°
Electrical Load . . . . . . . Up to 150 Watts Maximum

tungsten

Power Requirements . . 120 VAC, 60 Hz
Operating Modes . . . . . TEST, AUTO and MANUAL

MODE

Time Delay . . . . . . . . . 10 minutes
Sensitivity . . . . . . . . . . Adjustable
Replacement lamp . . . . T 150W (or less) halogen 120

VAC

HeathCo LLC reserves the right to discontinue prod-
ucts and to change specifications at any time without
incurring any obligation to incorporate new features in
products previously sold.

TEST AND ADJUSTMENT

Turn on the circuit breaker and light switch.

Maximum

Range

Maximum

Coverage Angle

NOTE: Sensor requires about 1

1

/

2

minutes to calibrate

before it will detect motion. When first turned
on, wait about 1

1

/

2

minutes.

Avoid aiming the control at:

• Objects that change temperature rapidly, such as

heating vents and air conditioners. These heat
sources could cause false triggering.

• Areas where

pets or traffic may trigger the control.

Nearby large, light-colored objects reflecting light
may trigger the shut-off feature. Do not point other
lights at the sensor.

50 ft.

(15.2 m)

The control is most sensitive to motion across it.

Least Sensitive

Most Sensitive

Motion

Sensor

Motion

Loosen the clamp screw in the

sensor ball joint and gently
rotate the sensor to aim.

Walk through the coverage

area noting where you are
when the lights turn on. Move
the sensor head up, down, or
sideways to change the cover-
age area.

Keep the sensor at

least 1" (25 mm) away from
the lamps.

Secure the sensor head into

position by tightening the
clamp screw.

Do not over-

tighten the screw.

Set the ON-TIME control to 10

minutes.

Bottom of Sensor

8 ft.

(2.4 m)

110°

Set the ON-TIME control to the TEST position.

Aim Sensor

Down for Short

Coverage

Aim Sensor

Higher for Long

Coverage

Clamp

Ball
Joint

ON-TIME

10

TEST

Advertising