Heat & Glo Fireplace 6000 XLT User Manual

Page 15

Advertising
background image

12

H

V

H

V

Figure 10. Venting with One 90° Elbow

VENTING WITH ONE (1) 90° ELBOW

V (FT.)

H (FT.) (8000 & 6000’s)

H (FT.) SL-42DVT

1' MIN. (305 mm) 6' MAX. (1.86 m)

3’ MAX. (914mm)

2' MIN. (610 mm) 12' MAX. (3.66 m)

6’ MAX. (1.83m)

3' MIN. (914 mm) 18' MAX. (5.58 m)

9’ MAX. (2.74m)

4' MIN. (1.22 m)

24' MAX. (8.44 m) 12’ MAX. (3.66m)

20' MAX. (6.2 m) 24' MAX. (8.44 m) 12’ MAX. (3.66m)

(21' IN CANADA 6.3 m)

NOTE: MODEL 6000 ARCH
A 12-INCH LENGTH OF STRAIGHT
VENT PIPE
MUST BE THE FIRST
VENT COMPONENT ATTACHED
TO THE UNIT.

FOR 8000DVTFL, 6000DVTFL, 6000XLT
NOTE: IF A 90° ELBOW IS FIRST
ATTACHED TO THE UNIT, THE MAXIMUM
HORIZONTAL RUN H IS 3-FEET (914 MM).

FOR SL-42DVT
NOTE: IF A 90° ELBOW IS FIRST
ATTACHED TO THE UNIT, THE
MAXIMUM HORIZONTAL RUN H IS
2-FEET (610 MM).

NOTE: For corner installations: A 6-inch (152mm) MINIMUM length of
straight pipe must be first attached to the fireplace before 90

O

eblow.

This will allow the vent pipe to clear the top standoffs.

Model 6000XLT & 8000DVTFL

Advertising