CHiMe ReplaCeMent installation

Note: Electrical work must be in accordance with national and local
electrical codes. If in doubt, consult a qualified electrician.
1. Verify transformer power rating. Power must be supplied from

a 16 Volt AC, 10 Watt or a 16 Volt AC, 15 Watt transformer
(Heath

®

/Zenith models 122C, 121AC, or 125C).

2. Remove cover from existing chime.
3. Label all wires before disconnecting. Using masking tape, mark

each wire according to existing chime terminal markings.
• “F” – Front Push Button Wire
• “T” – Transformer Wire
• “R” – Rear Push Button Wire*

4. Disconnect all wires from existing chime.
5. Remove existing chime base from wall.
6. Determine proper chime base orientation. The chime cover

style may determine orientation.

7. Determine cover mounting type. For hang pin and hole type

covers, hang pin should be installed before mounting base to
wall. Install hang pin by snapping into mounting hole or sliding
onto chime base, depending on type of hang pin (see Figures 1
and 3).

Illustrations may vary from actual chime unit.

Figure 1 - Mechanical Chime Identification

(Model 35 Base Shown)

FR

ON

T

REAR

TR

AN

S

Hang Pin, Snap-On
Type (Used for Hang
Pin and Hole Covers)

Base Orientation
Marking

Wire Entrance Hole

Mounting Slot (x4)

Tone Bars

Transformer and
Push Button Wire
Connections

Continued

Plungers

Hang Pin Mounting
Slot (Horizontal)

Hang Pin Mounting
Slot (Vertical)

Hang Pin, Slide-On Type
(Used for Hang Pin and
Hole Covers)

Advertising