Electronic Ignition System

1. Slide the 3-position button on the remote receiver to

the ON position. The spark electrode should begin
sparking to ignite the pilot (the pilot may ignite after
only one spark). After the pilot flame is lit, the main
gas valve should open and the main gas flame should
ignite.

2. Slide the button to OFF. The main gas flame and

pilot flame should BOTH extinguish.

3. Slide the button to REMOTE (the center position).

4. Then press the MODE button on the transmitter to

change the system to ON. The spark electrode
should begin sparking to ignite the pilot. After the
pilot is lit, the main gas valve should open and the
main gas flame should ignite.

5. Press the MODE button on the transmitter to OFF.

The main gas flame and pilot flame should BOTH
extinguish.

6. Press the MODE button on the transmitter to change

the system to THERMO.

7. Advance the SET temperature on the transmitter to

temperature of at least 1

0

F (-17

0

C) above the room

temperature displayed on the LCD screen and the
system flame will ignite.

8. Set the SET temperature to at least 2

0

F (1

0

C) below

the room temperature and the system will extinguish.
Thereafter, it should continue to cycle on and off ther-
mostatically approximately every two minutes as the
ROOM temperature changes, but only when the tem-
perature differential between ROOM and SET tem-
peratures differ at least 2

0

F (1

0

C). The 2

0

F (1

0

C)

differential is the factory setting.

Timer Operation
The countdown timer will operate in either the manual
ON or THERMO mode. Once the fireplace system is in
an operating mode, set the countdown timer to turn off
in 15 minutes. The timer function will allow operation to
continue until the “countdown time” on the LCD screen
expires. After 15 minutes elapses, the system should
turn off.

Limited Warranty

This REMOTE CONTROL SYSTEM is warranted
for 12 months from the date of purchase or instal-
lation to the original purchaser to be free from de-
fects in materials and workmanship. Damage to
the SYSTEM caused by accident, misuse, abuse,
or installation error whether performed by a con-
tractor, service company, or owner, is not covered
by this warranty. Seller will not be responsible for
labor charges and/or damage incurred in installa-
tion, repair, replacement or for incidental or con-

sequential damages. Batteries and any damage
caused by them are not covered by this warranty.

Some states, provinces, and nations do not allow
exclusion or limitations of incidental or consequen-
tial damages, so the above limitations or exclu-
sions may not apply. This warranty gives you spe-
cific legal rights. You may have other rights that
vary by state, province or nation.

GENERAL INFORMATION

Transmitter Wall Bracket
The transmitter can be hung on a wall using the bracket
provided. Locate the bracket on an inside wall sufficiently
far away from direct sources of heat such as a fire-
place, incandescent lighting, or sunlight so it detects
ambient room temperatures, not a single heat source. If
the bracket is installed on a solid wood wall, drill 1/8
inch pilot holes and install with the screws provided. If it
is installed on a plaster/wallboard wall, first drill two 1/4
inch holes into the wall, then use a hammer to tap in
the two plastic wall anchors flush with the wall, then
install the screws provided.

Battery Life
Life expectancy of the alkaline batteries in the transmit-
ter should be at least one season. Check batteries an-
nually. When the transmitter no longer operates the re-
mote receiver from a distance it did previously (i.e., the
transmitter’s range has decreased) the batteries should
be checked.

Specifications

Batteries: Transmitter - 3V 2 ea.; AAA 1.5V, Alkaline

Receiver - 110-120 VAC; 60Hz

Operating Frequency:
FCC ID No.’s:

Transmitter - ULERF-5A
Receiver - ULERF-5A

Canadian IC ID No.’s:

Transmitter -6732A-RF5A
Receiver -6732A-RF5A