598-1162-02

Maximum

Maximum Range

Coverage Angle

MAX

MIN

RANGE

ON-TIME

DUAL BRITE™

TEST 1 5 20

MINUTES

OFF 3 6 DUSK TO

DAWN

HOUR

BO

O

S

T

Motion

Motion

8 ft.

(2.4 m)

70 ft. 100 ft.

(21 m) (30.5 m)

Boosted

Sensor

240°

D

ual

Z

one

D

ual

Z

one

D

ual

Z

one

D

ual

Z

one

Bottom of Sensor

Avoid aiming the control at:

• Objects that change temperature rapidly, such as

heating vents and air conditioners. These heat
sources could cause false triggering.

• Areas where

pets or traffic may trigger the control.

Nearby large, light-colored objects reflecting light
may trigger the shut-off feature. Do not point other
lights at the sensor.

Least Sensitive

Most Sensitive

NOTE: D

ual

Z

one

™ is a new zone of detection which

was added as an option to select Heath

®

/Zenith motion

sensing products. This feature adds a zone of detec-
tion under the motion sensor. D

ual

Z

one

™ requires

no additional adjustment and operates in conjuction
with the forward-looking sensor.

Loosen the clamp screw in the

sensor ball joint and gently
rotate the sensor.

Walk through the coverage

area noting where you are
when the lights turn on (also,
the LED will flash several times
when motion is detected). Move
the sensor head up, down, or
sideways to change the cover-
age area.

Keep the sensor at

least 2" (51 mm) away from
the bulbs.

Adjust the RANGE as needed.

RANGE set too high may
increase false triggering.

Secure the sensor head by
tightening the clamp screw.

Do not overtighten the screw.

Set the amount of TIME you want the lights to stay

on after motion is detected (1, 5, or 20 minutes).

Set the D

ual

B

rite

®

switch to the amount of time

after dusk you want the lights on at low level (Off,
3, 6 Hrs., Dusk-to-Dawn).

Clamp
Screw

Ball
Joint

Aim Sensor

Down for Short

Coverage

Aim Sensor

Higher for Long

Coverage

TEST AND ADJUSTMENT

Turn on the circuit breaker and light switch.

NOTE: Sensor has a 1

1

/

2

minute warm up period

before it will detect motion. When first turned
on, wait 1

1

/

2

minutes.

NOTE: Meets the ENERGY STAR

®

guidelines when

D

ual

B

rite

®

function is off and ON-TIME is 1 or 5 mi-

nutes.

Turn the RANGE control to the medium position

(halfway between MIN and MAX), D

ual

B

rite

®

to OFF,

and the ON-TIME control to the TEST position.

NOTE: If fixture is mounted higher than 8 ft. (2.4 m), aiming
the sensor down will reduce coverage distance.
The detector is less sensitive to motion directly towards it.

WARNING - Risk of fire. Do not aim the bulbs

at a combustible surface within 3 ft. (1 m).