Isle royale wood stove – Hearth and Home Technologies 823-0170 User Manual

Page 20

Advertising
background image

R

Page 20

September 1, 2008

Isle Royale Wood Stove

250-5763C

WARNING! ALWAYS OPERATE THIS APPLI-

ANCE WITH THE DOOR CLOSED AND LATCHED

ExCEPT DURING START-UP AND RE-FUELING

OR WHEN USING THE FIRESCREEN.

NOTE:

See

page 21 for operation considerations with

a blower installed.

OPERATING THE TOP LOADING OPTION

NOTE: This stove is provided with 3 fiber door handles for

the door, baffle by-pass handle and the top-load-
ing griddle slot.

1. Using a 7/16 wrench, remove the 2 shipping bolts under-

neath the griddle before lifting the griddle off of stove.

2. Open by-pass door by moving the side handle towards

rear of stove.

3. Wait 15 seconds to allow smoke to clear out of firebox.
4. Slowly open top loading door and load unit with fuel.
5. Close the top door.
6. Close the by-pass door (move side handle towards front

of stove.)

CAUTION! SHIPPING BOLTS MUST BE REMOVED

PRIOR TO REMOVING GRIDDLE.

OPERATING INSTRUCTIONS (Cont’d)

HEAT OUTPUT SETTINGS

NOTE: These are approximate settings, and will vary

with type of wood or chimney draft. Due to altitude and

other environmental circumstances, this operation infor-

mation is a guideline only. Similar burn rates may be

obtained using other settings unique to your situation.

for maximum operating efficiency with the lowest emissions, follow these operating procedures:
1. Regardless of desired heat output, when loading stove, burn your Quadra-Fire with both air controls

wide open for 5 to 15 minutes.

2. Regulate burn rate (heat output) by using the Primary Air Slide Control (center under ashcatcher).

The Start-Up Air Control (on the right) is used for initial start-up and reloading.

3. Heat output settings are listed below, following 5 to 15 minutes of burning with controls wide open

(

see #1 above):

4. Burn dry, well-seasoned wood.

WARNING: Do not operate with Start-Up Air

Control in the open positionin excess of 15

minutes! Risk of extreme temperatures! Pro-

longed operation of this stove with the Start-

Up Air Control in the open position may cause

the combustible materials around the stove to

exceed safe temperature limits.

BTU / Hr

Below 10,000

10,000 - 15,000

15,000 - 40,000

Maximum Heat

Start-Up Air Control

Closed after 5 to 15 minutes

Closed after 5 to 15 minutes

Closed after 5 to 15 minutes

Closed after 5 to 15 minutes

*Primary Air Slide Control

Slide to right

1/8 to 1/2" open (slide to left)

1/2” to 1-1/8" open (slide to left)

Fully open (all the way left

CAUTION! IF THE DOOR HANDLE IS LEFT ON THE

STOVE DURING OPERATION, IT MAY OVERHEAT

AND CAUSE BURNS TO YOUR HAND, EITHER

REMOVE THE HANDLE DURING OPERATION,

OR WEAR PROTECTIVE GLOVES. ALSO, USE

CARE WHEN OPERATING THE DRAFT CONTROL

KNOBS AS THEY ALSO BECOME HOT DURING

OPERATION.