Advanced functions – Honeywell VisionPRO TH8000 Series User Manual
Page 25
VisionPRO
®
TH8000 Series
23
69-1894EFS—03
ENGLISH
Advanced functions
Program schedule on/off
Function
0160
Press
s
/
t
to turn the program schedule on or off:
Options:
0
Program schedule is off. Thermostat is non-programmable.
4
Program schedule is on (7-day programmable).
Temperature format (°F/°C)
Function
0320
Press
s
/
t
to set the temperature display format:
Options:
0
Fahrenheit
1
Celsius
Daylight savings time on/off
Function
0330
The thermostat is pre-programmed to automatically adjust to daylight savings time.
Press
s
/
t
to select an option:
Options:
0
Off: No adjustment for daylight savings time
1
On: Auto-change to daylight savings time (through 2006, and for areas that
do not use the new 2007 DST calendar)
2
On: Auto-change to daylight savings time (2007 and beyond, for areas that
use the new 2007 DST calendar)