F. install metal roof flashing, G. assemble and install storm collar – Heat & Glo Fireplace XLR-PLUS-PB-AU User Manual

Page 39

Advertising
background image

39

Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. o • 1/13

F. Install Metal Roof Flashing

• See minimum vent heights for various pitched roofs

(Figure 10.11) to determine the length of pipe to extend

through the roof.

• Slide the roof flashing over the pipe sections extending

through the roof as shown in Figure 10.12.

Figure 10.12

CAULK

NOTICE: Failure to properly caulk the roof flashing and

pipe seams could cause water entry.
• Caulk the gap between the roof flashing and the outside

diameter of the pipe.

• Caulk the perimeter of the flashing where it contacts the

roof surface. See Figure 10.12.

• Caulk the overlap seam of any exposed pipe sections

that are located above the roof line.

G. Assemble and Install Storm Collar

CAUTION! Risk of Cuts, Abrasions or Flying Debris.

Wear protective gloves and safety glasses during instal-
lation. Sheet metal edges are sharp.
• Connect both halves of the storm collar with two screws

(see Figure 10.13).

• Wrap the storm collar around the exposed pipe section

closest to the roof and align brackets. Insert a bolt

(provided) through the brackets and tighten the nut to

complete the storm collar assembly. Make sure the collar

is tight against the pipe section.

• Slide the assembled storm collar down the pipe section

until it rests on the roof flashing (see Figure 10.14).

• Caulk around the top of the storm collar (see Figure 10.15).

Figure 10.13 Assembling the Storm Collar

Figure 10.14 Assembling the Storm Collar Around the Pipe

H (MIN.) - MINIMUM HEIGHT FROM ROOF

TO LOWEST DISCHARGE OPENING

VERTICAL

WALL

TERMINATION

CAP

HORIZONTAL

OVERHANG

305 mm

X

ROOF PITCH

IS X/ 305 mm

LOWEST

DISCHARGE

OPENING

510 mm MIN.

610 mm MIN.

Figure 10.11 Minimum Height From Roof To Lowest

Discharge Opening

Angle

H (Min.) mm

0°-26.6° .......................................................... 500*
26.6°-30.3° .......................................................... 500*
30.3°-33.7° .......................................................... 500*
33.7°-36.9° .......................................................... 610*
36.9°-39.8° .......................................................... 760
39.8°-42.5° .......................................................... 990
42.5°-45.0° ........................................................1 220
45.0°-49.4° ........................................................1 520
49.4°-53.1° ........................................................1 830
53.1°-56.3° ........................................................2 130
56.3°-59.0° ........................................................2 290
59.0°-60.3° ........................................................2 440

*910 mm minimum in snow regions

Advertising