Failure code – haier AS072XHERA User Manual

Page 32

Advertising
background image

30

Failure code

Note:

1. Please contact the installers or distributors when trouble happens to repair it.

2. Turn the power off and power on again, if the failure code recurs, please change the indoor unit PCB.

3. Failrue codes maked with are resumable.

TROUBLE SHOOTING

FAILURE CODE
(TIMER LED OF INDOOR
RECEIVER BOARD FLASHES
TIMES)

POSSIBLE REASONS

Faulty temperature sensor Tai

ONCE

Sensor disconnected, or broken, or at wrong
position, or short circuit

Faulty temperature sensor Tc1

Sensor disconnected, or broken, or at wrong
position, or short circuit

Faulty temperature sensor Tc2

3 TIMES

Sensor disconnected, or broken, or at wrong
position, or short circuit

Faulty temperature sensor Tm

4 TIMES

Sensor disconnected, or broken, or at wrong
position, or short circuit

Faulty EEPROM on indoor
unit PCB

5 TIMES

Faulty indoor unit PCB

Abnormal communication
between indoor and outdoor unit

6 TIMES

Wrong connection, or the wires be disconnected,
or wrong address setting of indoor units, or faulty
PCB, or faulty power supply

Indoor unit address repeated

9 TIMES

Wrong setting of indoor unit address

Central control address repeated

10 TIMES

Wrong setting of centralized control indoor unit
address

Faulty indoor unit fan motor

11 TIMES

Fan is blocked, or the terminal is disconnected
from the PCB, or faulty indoor unit PCB

Faulty driver of indoor unit
fan motor

12 TIMES

Faulty indoor unit PCB

Malfunction on outdoor unit

20 TIMES

Check the outdoor unit

TWICE

Advertising