Optional wiring – Heath Zenith Motion Sensing Coach Lights User Manual

Page 4

Advertising
background image

4

598-1207-01

OPTIONAL WIRING

This fixture is provided with a sensor rated for 360 Watts. Since the fixture is only rated 100
Watts, 260 Watts of additional load may be controlled by this sensor.
When determining what a fixture is rated for, do not simply look at the rating on the lamp in
the fixture. Look at the marking which specifies the maximum lamp wattage for which the
fixture is suitable.
Once you have selected the fixtures to be connected and determined their maximum ratings,
add these ratings up. For instance, if you have 3 fixtures rated 100 Watts, 150 Watts, and
75 Watts respectively, you have a total load of 325 Watts.
Wiring Diagram 1 – When wiring to control a standard light fixture: Strip the motion sensor’s
red wire and connect to the standard light’s black wire. Connect all white wires together.
Total fixture ratings must not exceed 360 Watts (3.0 A).
Wiring Diagram 2 – When wiring to control another motion sensing light fixture (Master /
Slave): Strip the red wire in both light fixtures. Connect the red wire of the controlling (master)
fixture to the red and black wires of the controlled (slave) fixture. Connect all white wires
together. Total fixture ratings must not exceed 360 Watts (3.0 A).

Wiring Diagram 1

Black

White

Green

or Bare

Light

Fixture

Light

Fixture

Wiring Diagram 2

(Standard)

Master

Slave

Black

White

Green

or Bare

Light

Fixture

Light

Fixture

Red

Red

Advertising