Troubleshooting guide, Specifications, Technical service – Heath Zenith Wireless Lamp/Outlet Modules 6138 User Manual

Page 3

Advertising
background image

-3-

595-5627-04

TROUBLESHOOTING GUIDE

SYMPTOM

Appliance does not
come on.

Appliance does not
turn off.

Appliance comes
on randomly.

POSSIBLE CAUSE

1. Circuit breaker or fuse is turned off.
2. Switch on appliance is turned off.
3. Lamp or appliance is defective.
4. Signals from remote switch are being blocked, or

remote switch is out of range. Check for metal ob-
jects that could block the signal, or reposition the
remote switch.

5. Weak battery in the remote switch.
1. Switching too fast. Wait 3 seconds before switch-

ing the remote switch.

2. Same as 4 & 5 above.
1. Short term power line failure.
2. Another remote switch on the same channel.

SPECIFICATIONS

Range ...............................................Up to 100 feet (30.5 m)

Rated Voltage ...................................120 VAC, 60 Hz

Maximum Load SL-6136 ..................Up to 500 Watts Maximum, Incandescent

Up to 400 Watts Maximum, TV

Up to 300 Watts Maximum, Fluorescent

Up to 1/3 H.P. Motor Maximum

Maximum Load SL-6138 ..................Up to 150 Watts Maximum, Incandescent

Battery ..............................................9-volt alkaline

TECHNICAL SERvICE

Please call 1-800-858-8501 (English speaking only) for assistance

before returning product to store.

If you experience a problem, follow this guide. You may also want to visit our Web
site at:

www.hzsupport.com. If the problem persists, call* for assistance at 1-800-

858-8501 (English speaking only), 7:30 AM to 4:30 PM CST (M-F). You may also
write* to:
HeathCo LLC
P.O. Box 90004, Bowling Green, KY 42102-9004
ATTN: Technical Service
* If contacting Technical Service, please have the following information available:
Model Number, Date of Purchase, and Place of Purchase.

No Service Parts Available for this Product

Advertising