Honeywell 7351F User Manual

Page 17

Advertising
background image

Model

Schedule Options

User

Interface

Application

Power

Method

Feat ures and Functions

Display

Information

Warranty

Replacements

Sensor

Compatibility

Pr

ogram Options

ENERGY

ST

AR

®

Temporar

y Override

Holiday

Conventional

Heat Pump

Modulating

Fan Coil

PT

AC

R

ea

l T

im

e

C

lo

ck

(Automatically

Updates

Daylight

Savings)

Per

manent

Memor

y

Retention

Recover

y Ramps

LonW

orks

®

C

om

m

m

un

ic

at

in

g

Capability

Economizer

Output

M

ul

tip

le

K

ey

pa

d

Lockout Levels

Dehumidification

Contr

ol

Remote Sensing

Display

Size

(V

iewable)

On-Demand

Backlighting

Continuous Backlighting

Si

m

ul

ta

ne

ou

s

D

is

pl

ay

o

f

Room and Set T

emperatur

e

Honeywell

White-Rodgers

Invensys/Rober

tshaw

Carrier/T

otaline

TCS Basys

T7351F2010

365-

Day

Yes

Yes

Yes

Soft

Keys

3 Heat/

3 Cool or

2 Heat/

4 Cool

3 Heat/

2 Cool

No

24 Vac

Yes

Yes Yes

No

Yes

Yes

(4)

Yes

Yes (Indoor,

Outdoor,

Discharge,

Humidity,

Occupancy)

4.2 sq. in. No Yes

No

1 Year

All T7300s

with non-

Q7300H

subbases

All

White-

Rodgers

Thermostats

All Invensys/

Robertshaw

Thermostats

All Carrier/

Totaline

Thermostats

SZ1022,
SZ1024,
SZ1031,
SZ1033,
SZ1035,

SZ1009

T7771A1005,

TR21,

TR21-A

(averaging),

TR22,
TR23,
TR24,

C7772A1012

(flush mount),

C7770A1006

(return airduct),

C7041P2004

(button sensor)

TB8220U1003

7-Day Yes

Yes

(Cumulative)

Yes

Touch-
screen

2 Heat/

2 Cool

3 Heat/

2 Cool

No

24 Vac

or

Battery

Yes

Yes Yes

No

Yes

Yes

(4)

No

Yes

(Indoor or

Outdoor)

10 sq. in. Yes Yes Yes

5 Years

T7300 with

Q7300A2016,
Q7300A2008,

Q7300C2004

and

Q7300C2012

subbase

1F90 series,

1F80 series

9800 series,

9700i series,

300 series

P374-2100,
P374-2200,
P374-2300,

33CS250-01,
33CS220-01,
33CS071-01,

33CSSP2-WC,

33CSSN2-WC

TR21,

TR21-A

(averaging),

C7772A1012

(flush mount),

C7770A1006

(return air duct),

C7041P2004

(button sensor)

TB7220U1012 7-Day Yes

Yes

(Cumulative)

Yes

Soft

Keys

2 Heat/

2 Cool

3 Heat/

2 Cool

No

24 Vac

or

Battery

Yes

Yes Yes

No

Yes

Yes

(4)

No

Yes

(Indoor or

Outdoor)

4 sq. in. Yes Yes Yes

2 Years

T7300 with

Q7300A2016,
Q7300A2008,

Q7300C2004

and

Q7300C2012

subbase

1F90 series,

1F80 series

9800 series,

9700i series,

300 series

P374-2100,
P374-2200,
P374-2300,

33CS250-01,
33CS220-01,
33CS071-01,

33CSSP2-WC,

33CSSN2-WC

TR21,

TR21-A

(averaging),

C7772A1012

(flush mount),

C7770A1006

(return air duct),

C7041P2004

(button sensor)

TB7100A1000

7-Day Yes

Yes

(Cumulative)

Yes

Soft

Keys

1 Heat/

1 Cool

2 Heat/

1 Cool

No

2 or

4-pipe

2 Heat/

1 Cool

24 Vac

or

Battery

Yes

Yes Yes

No

No

Yes

(5)

No

Yes

(Indoor or

Occupancy)

4 sq. in. Yes Yes Yes

2 Years

T8574B2016,
T8575B2007,
T8575C2005,

T8575D2003

IF90-371,
IF96-344,
IF97-371,
IF80-224,
IF80-241,
IF80-261,
IF86-244,
IF87-251,
IF82-261,

IF89-211

97012,

9610,

9700i,

300-224,
300-225,
300-226,

P274-0100,
P274-1100,
P374-0200,

P374-0300

SZ1-61,
SZ1062

TR21,

TR21-A

(averaging),

C7772A1012

(flush mount),

C7770A1006

(return air duct),

C7041P2004

(button sensor)