InDICATOrS AnD ADjUSTMEnTS, COnT.

1. remove the thermostat from the wall plate.
2. To make your system run lOnGEr, turn the

s

pan

a

djust

clockwise.

3.

To make your system run SHOrTEr, turn the

s

pan

a

djust

counter clockwise.

4. reattach the thermostat to the wall plate.

note: The Span range is 0.6

o

F - 3

o

F. The Span setting remains

the same in both the Heat and Cool modes and can be
changed regardless of what position the System Switch is in.

Your thermostat is preset to cycle your system

off and on at 1

o

F above and below the Set

Temperature. For maximum system efficiency and

a sustained comfortable temperature your system

should cycle 3 - 5 times per hour. If your system is

cycling either too often or not often enough, then

use a small Phillips-head screwdriver

to turn the

s

pan

a

djust

left or right to change the cycle time.