Specifications, Troubleshooting guide, No service parts available for this product – Heath Zenith 5105 User Manual

Page 5

Advertising
background image

5

598-1202-01

SPECIFICATIONS

Range . . . . . . . . . . . . Up to 70 ft. (21 m); 100 ft.

(30.5 m) with Range Boost. [varies
with surrounding temperature]

Vertical Range . . . . . . Up to 15 ft. (4.6 m)
Sensing Angle . . . . . . Up to 240° horizontal. Up to 80°

Vertical

Electrical Load . . . . . . Up to 300 Watt Maximum In-

candescent [Up to 150 Watt
maximum each bulb holder.]

SYMPTOM

Lights will not come

on.

Lights come on

in daylight.

Lights come on for

no apparent rea-

son.

Lights turn off too

late in Dusk-to-

Dawn setting

POSSIBLE CAUSE

1. Light switch is turned off.

2. F l o o d l i g h t i s l o o s e o r

burned out.

3. Fuse is blown or circuit breaker

is turned off.

4. Daylight turn-off is in effect (re-

check after dark).

5. Incorrect circuit wiring, if this is

a new installation.

6. Re-aim the sensor to cover de-

sired area.

1. Light control may be installed in

a relatively dark location.

2. Light control is in Test.

(Set control switch to an

ON-TIME position).

1. Light control may be sensing

small animals or automobile

traffic (re-aim sensor).

2. R a n g e i s s e t t o o h i g h .

(Reduce Range).

3. D

ual

B

rite

®

Timer is on.

1. Sensor is in a relatively dark

location. (Relocate sensor, or

use 3 hr or 6 hr setting.)

SYMPTOM

Lights stay on

continuously.

Lights flash on

and off.

Lights flash

once, then stay

off in Manual

Mode.

POSSIBLE CAUSE

1. A flood bulb is positioned too close to

the sensor or pointed at nearby objects

that cause heat to trigger the sensor.

(Reposition the bulb away from the

sensor or nearby objects).

2. Light control is pointed toward a heat

source like an air vent, dryer vent, or

brightly-painted heat-reflective surface.

(Reposition sensor. Reduce Range).

3. Light control is in Manual Mode. (Switch

to Auto.)

1. Heat or light from the bulbs may be

turning the light control on and off.

(Reposition the bulbs away from the

sensor).

2. Heat being reflected from other objects

may be affecting the sensor. (Reposi-

tion sensor).

3. Light control is in the Test mode and

warming up. (Flashing is normal under

these conditions. Turn Boost off.)

4. Light may be leaking through the flood-

lamp reflectors. (Replace the bulbs

with new high quality PAR 38 bulbs or

make sure the metal bulb protectors

are installed).

1. Sensor is detecting its own lights.

(Reposition bulbs to keep area below

the sensor relatively dark.)

See your Canadian Tire retailer for warranty information.

Power Requirements . 120 VAC, 60 Hz
Operating Modes . . . . TEST, AUTO and MANUAL

MODE

Time Delay . . . . . . . . 1, 5, 20 minutes
D

ual

B

rite

®

Timer . . . . 3, 6 hours, Dusk-to-Dawn

HeathCo LLC reserves the right to discontinue prod-
ucts and to change specifications at any time without
incurring any obligation to incorporate new features
in products previously sold.

TROUBLESHOOTING GUIDE

If you experience a problem with this product, follow this guide before returning it to the retailer.

No Service Parts Available for this Product