Model CBC/CBR-103,104,105,106,107

2-2. UNPACKING

Take care when moving the unit to prevent personal
injury or damage to the refrigeration system. The units
weigh between 400 (182 kg) and 580 lbs. (263 kg).

4.

Peel off any protective covering from exterior of the cabinet.

5.

Install the grids into unit.

6.

Your cold base is now ready for operation.

2-3. ELECTRICAL

The cold base is available as a 120 VAC, 60 Hz. or 230VAC,
50Hz, single phase unit, both for domestic and international use.
The data plate, located beside the power cord, specifies the correct
electrical supply. The cold bases are shipped with cord and plug,
and requires a grounded receptacle with a separate electrical line
protected by a fuse or circuit breaker of the proper rating. Position
the unit so the power cord receptacle is accessible.

To avoid electrical shock, this appliance must be
equipped with an external circuit breaker which will
disconnect all ungrounded (unearthed) conductors.

Refer to the table below for electrical ratings:
Model No.

Volts

Amps

Phase

Max. Fuse Size

CBC-103

120

8.1

1

15

CBC-103

230

5.8

1

15

CBC-104

120

8.1

1

15

CBC-104

230

7.3

1

15

CBC-105

120

9.5

1

15

CBC-105

230

7.5

1

15

CBC-106

120

9.5

1

15

CBC-106

230

7.5

1

15

CBC-107

120

9.5

1

15

CBC-107

230

7.7

1

15

(Continued)