Holmes X Carbon HM1745 User Manual

Page 2

Advertising
background image

HOW COOL MIST WORKS

Your Holmes Cool Mist humidifier draws dry air through the rear

air intake grill area. This air is then passed through a moisture-

laden wick filter, which retains the minerals and deposits in the

water. The resulting moist air is directed back into the room from

the top air grill.
NOTE: This humidification system provides a cool, invisible

moisture output. It is normal not to see the mist.
NOTE: A humidity level below 20% can be unhealthy and

uncomfortable. The recommended humidity level is between

40%-50%.

PRE-OPERATING INSTRUCTIONS

1. Be sure the humidifier is switched OFF and disconnected from

the electrical outlet.

2. Select a location for your humidifier, on a flat surface, about 4"

away from the wall. Do not place your humidifier on furniture;

a floor location that will not be damaged by moisture is best.

3. Remove the water tank by holding the tank handle and lifting

straight upward (see Figure 1 and 2).

4. Remove the main housing by lifting straight upward. Check to

see that the wick filter is properly in place. Replace the

humidifier housing.

FILLING THE WATER TANK

NOTE: This humidifier holds about 1.4 gallon of water in the

tank and humidifier base. The humidifier will produce up to 3.0

gallons of moisture over a 24-Hour period, depending on the

room humidity and temperature.
1. Be sure the humidifier is switched OFF and disconnected from

the electrical outlet.

2. Remove the tank from the base by holding the handle and lift-

ing straight up (see Figure 1 and 2).

3. Twist off the tank cap located on the bottom of the tank by

turning counter clockwise and fill the water tank with cool,

fresh water. Do not fill with warm water as this may

cause leaking.

4. After filling the tank, replace the tank cap by firmly turning

clockwise and then replace the water tank on the base. The

tank will immediately begin to empty into the base.

5. Plug the power cord into a 120V AC electrical outlet.

OPERATING INSTRUCTIONS

1. Move the Humidity Control Knob to the HI position. Move the

Humidity Control knob to the LO setting to lower the humidifi-

cation rate. Allow up to 30 minutes for the filter to fully absorb

water and the unit to produce the maximum moisture output.

NOTE: We recommend the use of the hygrometer which you can

purchase by calling 1-800-5-HOLMES. A humidity level below

20% can be unhealthy and uncomfortable. The recommended

humidity level is between 40% and 50%.
2. When the water tank is empty, and the base is almost empty,

you need to refill the tank. The fan will continue to run to help

dry the humidifier. Shut off and unplug the unit. Please follow

the Daily Cleaning Instructions. Refill the tank as directed in

Pre-operating Instructions.

3. Make sure the unit is switched OFF, then plug into the electri-

cal outlet. Turn the power ON.

If you do not plan to use the humidifier for two or more days,

make sure any residual water is drained from the water tank,

base and wick filter to prevent algae or bacteria growth.

REPLACING THE FILTER

Through normal use, water borne minerals and sediment become

trapped in the wick filter. The harder your water, the greater the

amount of minerals in the water, and the more often you will

need to change your filter.
You will be able to monitor the life of the filter in your humidifi-

er by checking the FilterCheck

®

Indicator. When the unit is off,

the FilterCheck

®

Indicator will read in the OFF position. After 60

minutes of use, FilterCheck

®

Indicator (refer to Figure 3 for

close-up of indicator) will move from the OFF position and indi-

cate your filter condition. A brand new filter will register in the

blue section reading GOOD filter. After frequent use of your

humidifier, the FilterCheck

®

Indicator will let you know when the

filter needs to be changed.
When the needle is in the light blue

(CHANGE) section, this means the prop-

er amount of moisture is not getting

into your air due to the excessive min-

erals and sediment that have become

trapped on your filter. At this point, you

should replace your filter. It is impor-

tant to change your filter as indicated to

obtain stated performance level.
To replace the filter, follow the steps below.
1. Be sure the humidifier is switched OFF and disconnected from

the electrical outlet.

2. Remove the tank and main housing to access the base tray

(see Figures 1 and 2).

3. Discard the old filter and follow weekly cleaning instructions.
4. Insert a new filter into the filter support in the base (Figure 2).
5. Replace the main housing and then the tank.
6. Repeat Operating Instruction steps.
It will take about 30 minutes for the humidifier to reach

maximum output.
NOTE: You can purchase replacement filters (model HWF64)

at a local retailer, by calling 1-800-5-HOLMES, filling out the

accessory card, or by visiting www.holmesproducts.com. It is

recommended that a replacement filter is purchased for uninter-

rupted use.

CLEANING AND MAINTENANCE INSTRUCTIONS

Humidifiers provide comfort by adding moisture to dry indoor

air. To get the most of the benefit from the humidifier and avoid

product failure, follow all maintenance instructions carefully.

If the recommended care and maintenance guidelines are not

followed, micro-organisms may be able to grow in the water

within the humidifier.

Daily Maintenance

1. Be sure the humidifier is switched OFF and disconnected from

the electrical outlet.

2. Lift off the tank and the housing of the humidifier. Remove

filter and place in sink or tub as the filter will release water

when not in the humidifier.

3. Carry the base and the tank to the sink, remove the wick

filter, then drain and rinse the base and tank thoroughly to

remove any sediment and dirt. Wipe clean and dry with a

clean soft cloth or paper towel. (DO NOT use metal cleaning

utensils or abrasive cleaners)

4. Put the filter back in the filter supports, replace the housing,

then refill the tank with cool tap water as instructed in filling

the water tank instructions.

Weekly Maintenance

Remove scale:
1. Repeat steps 1-3 above.
2. Clean the base by partially filling the base with one 8-oz cup

of undiluted white vinegar, or by using CleanseClean

®

by

Holmes. Let solution stand 20 minutes, clean all interior

surfaces with a soft brush.

3. Dampen a cloth with undiluted white vinegar and wipe out

entire base to remove scale.

4. Rinse with clean warm water to remove scale and the white

vinegar solution before beginning to disinfect the tank.

Disinfect tank:
1. Fill tank with 1 teaspoon of chlorine bleach and 1 gallon of

water.

2. Let the solution stand for 20 minutes, swishing every few

minutes. Wet all surfaces.

3. Empty the tank after 20 minutes, and rinse well with water

until the bleach smell is gone. Dry with a clean cloth or paper

towel.

4. Refill the water tank with cool water; replace the housing

and the water tank. Repeat ALL Operating Instructions.

P L E A S E R E A D A N D S AV E T H E S E

I M P O R TA N T S A F E T Y I N S T R U C T I O N S

C L E A N I N G / M A I N T E N A N C E

R E P L A C I N G T H E F I LT E R

F E AT U R E S - O P E R AT I O N S

When using electrical appliances, basic safety precautions should

always be followed to reduce the risk of fire, electric shock, and

injury to persons, including the following:
1. Read all instructions before using the appliance.
2. To avoid fire or shock hazard, plug the appliance directly into a

120V AC electrical outlet.

3. Keep the cord out of heavy traffic areas. To avoid fire hazard,

NEVER put the cord under rugs or near heat registers.

4. DO NOT place humidifier near heat sources such as stoves, radi-

ators, and heaters. Locate your humidifier on an inside wall

near an electrical outlet. The humidifier should be at least 4”

away from the wall for best results.

5. NEVER place humidifier in an area where it is accessible to chil-

dren. NEVER use humidifier in a closed room, particularly where

a child may be sleeping, resting, or playing (a closed room may

result in excessive humidity).

6. WARNING: Do not attempt to refill humidifier without first

unplugging the unit from its electrical outlet. Failure to heed this

warning may cause personal injury. Be sure to unplug the unit by

pulling on the plug and not the cord.

7. Never place anything over moisture outlet when the unit is running.
8. NEVER drop or insert any object into any openings unless instruct-

ed in this manual.

9. DO NOT operate any appliance with a damaged cord or plug,

after the appliance malfunctions, or if it has been dropped or

damaged in any manner. Return appliance to manufacturer for

examination, electrical or mechanical adjustment, or repair.

10.Use appliance only for intended household use as described in

this manual. Any other use not recommended by the manufac-

turer may cause fire, electric shock, or injury to persons. The use

of attachments not recommended or sold by the manufacturer

may cause hazards.

11.DO NOT use outdoors.
12.Always place humidifier on a firm, flat, level surface. A water-

proof mat or pad is recommended for use under the humidifier.

NEVER place it on a rug or carpet, or on a finished floor that

may be damaged by exposure to water or moisture.

13.DO NOT allow the Moisture Outlet to directly face the wall.

Moisture could cause damage, particularly to wall paper.

14.Humidifier should be unplugged when not in use.
15.NEVER tilt, move, or attempt to empty unit while it is operating. Shut

off and unplug before removing the water tank and moving the unit.

16.This humidifier requires daily and weekly maintenance to operate

appropriately. Refer to daily and weekly cleaning procedures. Use

only cleaners and additives recommended by the manufacturer.

17.NEVER use detergents, gasoline, glass cleaner, furniture polish, paint

thinner, or other household solvents to clean any part of the humidifier.

18.Excessive humidity in a room can cause water condensation on

windows and some furniture. If this happens, turn the humidifier OFF.

19.Do not use humidifier in an area where humidity level is in excess

of 50%. Use a hygrometer, available at your local retailer or

through the manufacturer, to measure the humidity.

20.DO NOT attempt to repair or adjust any electrical or mechanical

functions on this unit. Doing so will void your warranty. The

inside of the unit contains no user serviceable parts. All servic-

ing should be performed by qualified personnel only.

21.Never place housing under water flow or immerse in liquids.
22.Do not plug in the cord with wet hands: electric shock could result.
23.Do not pour water in any openings other than the water tank.
24.To prevent damage to surfaces, do not place humidifier under

overhanging surfaces.

25.NEVER operate unit without water in the tank.
26.Do not move unit after it has been used until unit cools completely.
27.Use both hands when carrying full tank of water.

PLEASE READ AND SAVE

THESE IMPORTANT

SAFETY INSTRUCTIONS

Consumer Safety Information

NOTE: This is an electrical appliance and requires attention when

in use.
NOTE: If moisture forms on the walls or windows of the room,

turn off the humidifier. The room already has plenty of humidity

and additional moisture may cause damage.
NOTE: DO NOT block air inlet or outlet.

Cord and Plug Installation Safety Instructions

The length of cord used on this appliance was selected to reduce

the hazards of becoming tangled in, or tripping over a longer

cord. If a longer cord is necessary an approved extension cord

may be used. The electrical rating of the extension cord must be

equal to or greater than the rating of the humidifier. Care must

be taken to arrange the extension cord so that it will not drape

over the countertop or tabletop where it can be pulled on by

children or accidentally tripped over.

THIS PRODUCT IS EQUIPPED WITH A POLARIZED AC

(Alternating Current) PLUG (a plug having one blade wider

than the other). This plug will fit into the power outlet only

one way. If the plug does not fit fully into the outlet,

reverse the plug. If it still does not fit, contact qualified

personnel to install the proper outlet.

DO NOT DEFEAT THE SAF.ETY PURPOSE OF THIS

POLARIZED PLUG IN ANY WAY

Figure 3

Figure 1

A. Carry Handle
B. Humidifier Tank
C. FilterCheck

®

Indicator

D. Humidifer Housing
E. 3-Speed Humidity Control
F. Humidifier Base

A

D

B

E

Figure 2

A

C

B

F

C

A. Circular Extended Life Filter
B. Humidifier Base
C. Circular Filter Supports

HM174504EM1.qxd 5/11/04 15:50 Page 2

Advertising