Ac operation, 33 operation – HONDA EM5000is User Manual

Page 35

Advertising
background image

33

OPERATION

AC OPERATION

120V/240V

120V ONLY

VOLTAGE SELECTOR SWITCH

OUTPUT
INDICATOR
(GREEN)

OVERLOAD
INDICATOR
(RED)

If an appliance begins to operate abnormally, becomes sluggish, or
stops suddenly, turn it off immediately. Disconnect the appliance, and
determine whether the problem is in the appliance or the rated load
capacity of the generator has been exceeded.

Substantial overloading that continuously lights the overload indicator
(red) may damage the generator. Marginal overloading that
temporarily lights the overload indicator (red) may shorten the service
life of the generator.

Turn the voltage selector switch to either position.
With the voltage selector switch in the ‘‘120/240V’’ position, you can
use the 120V and 120/240V receptacles simultaneously. If you are
NOT using the 120/240V receptacle but require more power from the
120V locking plug receptacle, then select the ‘‘120V ONLY’’ position.

Start the engine and make
sure the green output
indicator comes on
(see pages

).

1.

2.

27

29