Ac receptacle selection, Power producing circuits, 36 operation – HONDA EM5000is User Manual

Page 38

Advertising
background image

36

OPERATION

AC Receptacle Selection

Power Producing Circuits

RECEPTACLE

1

TERMINAL 4A

RECEPTACLE

2

RECEPTACLE

4

TERMINAL 4B

RECEPTACLE

3

VOLTAGE
SELECTOR
SWITCH

120 V/240 V

120 V ONLY

POWER
CIRCUIT 1

POWER CIRCUIT 1

POWER
CIRCUIT 2

POWER CIRCUIT 2

The control panel, shown below, has a voltage selector switch and
four receptacles. Receptacle

4, the 240-volt receptacle, has two

powered terminals, 4A and 4B.

This generator is equipped with two power generating circuits. When
the voltage selector switch is in the 120V/240V position, each of the
two power producing circuits supplies power to specific receptacles.
When the voltage selector switch is in the 120V ONLY position, the
power producing circuits operate in parallel, sharing the total load
connected to terminal 4A and receptacles 1, 2, and 3.

07/12/21 14:03:19 31Z11710_037

Advertising