Voltage selector switch, 37 operation – HONDA EM5000is User Manual
Page 39
37
OPERATION
Receptacle
Switch Position
Available Power
120V ONLY Position
120V/240V Position
Power Producing
Circuit
Voltage Selector Switch
Set of
Receptacles
Total Current
Available
The power available to each receptacle depends on the position of the
voltage selector switch.
1
2
3
4A
4B
1
2
3
4A-4B
120 V ONLY
120 V/240 V
30 A at 120 V
20 A at 120 V
20 A at 120 V
30 A at 120 V
None
18.8 A at 120 V
18.8 A at 120 V
18.8 A at 120 V
18.8 A at 240 V
1
2
1
3
4B
2
4A
18.8 A
18.8 A
When the voltage selector switch is in the 120V ONLY position, you do
not need to spread the load over the receptacles. You must, however,
make sure the load on any receptacle does not exceed its available
power shown in the preceding table and the total load does not
exceed 37.5 amps.
When the voltage selector switch is in the 120V/240V position, you
must balance the load. Divide the load between the two sets of
receptacles shown below. Balancing is necessary because each set of
receptacles is powered by only one power producing circuit that can
produce a maximum of 18.8 amps.
07/12/21 14:03:28 31Z11710_038