Voltage selector switch, 37 operation – HONDA EM5000is User Manual

Page 39

Advertising
background image

37

OPERATION

Receptacle

Switch Position

Available Power

120V ONLY Position

120V/240V Position

Power Producing

Circuit

Voltage Selector Switch

Set of

Receptacles

Total Current

Available

The power available to each receptacle depends on the position of the
voltage selector switch.

1
2
3

4A

4B

1
2
3

4A-4B

120 V ONLY

120 V/240 V

30 A at 120 V
20 A at 120 V
20 A at 120 V
30 A at 120 V

None

18.8 A at 120 V
18.8 A at 120 V
18.8 A at 120 V
18.8 A at 240 V

1
2

1

3

4B

2

4A

18.8 A
18.8 A

When the voltage selector switch is in the 120V ONLY position, you do
not need to spread the load over the receptacles. You must, however,
make sure the load on any receptacle does not exceed its available
power shown in the preceding table and the total load does not
exceed 37.5 amps.

When the voltage selector switch is in the 120V/240V position, you
must balance the load. Divide the load between the two sets of
receptacles shown below. Balancing is necessary because each set of
receptacles is powered by only one power producing circuit that can
produce a maximum of 18.8 amps.

07/12/21 14:03:28 31Z11710_038