Troubleshooting & Diagnostics

Diagnostic Information


77







Troubleshooting

Table 18. Disk Module Additional Sense Code/Qualifier Codes

Byte

12-13


Description

00 00h

No Additional Sense information

01 00h

No index/sector signal

02 00h

No seek complete

03 00h

Peripheral device write fault

04 00h

LUN not ready; cause not reportable

04 01h

LUN not ready; becoming ready

04 02h

LUN not ready; initializing command required

04 03h

LUN not ready; manual intervention required

04 04h

LUN not ready; format in progress

08 00h

LUN communication failure

08 01h

LUN communication time-out

08 02h

LUN communication parity error

09 00h

Track following error

09 04h

Head select fault

0A 00h

Error log overflow

0C 00h

Write error

0C 01h

Write error recovered with auto-reallocation

0C 02h

Write error; auto-reallocation failed

10 00h

ID CRC or ECC error

11 00h

Unrecovered read error

11 01h

Read retries exhausted

11 02h

Error too long to correct

11 04h

Unrecovered read error; auto reallocation failed

12 00h

Address mark not found for ID field

12 01h

Recovered data without ECC using previous sector ID

12 02h

Recovered data with ECC using previous sector ID

14 00h

Sector not found

14 01h

Record not found

15 00h

Random positioning error

15 01h

Mechanical positioning error

15 02h

Positioning error detected by read of medium

16 00h

Data synchronization mark error

17 00h

Recovered data with no error correction applied

17 01h

Recovered data using retries

Advertising