Hoshizaki ROX-20TA-U User Manual

Page 35

Advertising
background image

33

U8AA5540012

Lamp

Service

Call

Code

E61

E62

E65

Problem

Flow switching
valve direction
microswitch turns
ON and OFF 5
times in 2 min.

Programmable
controller outputs
to flow switching
valve gear motor
for 20 sec.

After gear motor
stops, location
microswitch turns
ON.

Check

Gear Motor

Location Microswitch

Microswitch

Gear Motor

Possible Cause

Will not stop.

Fails to detect.

Fails to detect.

Overrun.

Remedy

Repair or replace.

Repair or replace.

Repair or replace.

Repair or replace.

* When restarting the electrolyzer after a shutdown for some error, check the amperage and

voltage on the electrolytic cell with an ammeter and voltmeter (not those provided on the
electrolyzer). If the voltage reading is normal but the amperage is still low, the salt water
inlet can be clogged or the salt water may be too thin. If both amperage and voltage are too
low, check for abnormal DC power supply or a bad contact of the relay or magnetic contactor.

* The electrolyzer may also shut down for some error when the flow rate varies for acid water

and alkaline water because of different piping resistance (ex. connecting hose crushed or
one of the water outlets under water). Even if the electrolyzer is in operation, varying flow
rate may cause low pH and chlorine concentration. Keep a constant flow rate by balancing
the piping resistance.

* The amperage varies with the salt water concentration and metering pump stroke speed.

When restarting the electrolyzer after a shutdown for some error, check the change in
amperage and the metering pump operation.

Advertising