Test and adjustment, Specifications – Heath Zenith Replacement Motion Sensor SL-5407 User Manual

Page 3

Advertising
background image

-3-

595-5544-06

Motion

Least Sensitive

Most Sensitive

Sensor

Motion

The sensor is less sensitive to motion directly to-
wards it, most sensitive to motion across its field
of view.

Maximum Range

Maximum

Coverage Angle

8 ft.

(2.4m)

70 ft.

(21m)

TEST AND ADJUSTMENT

Turn on the circuit breaker and light switch.

NOTE: Sensor has a 1

1

/

2

minute calibration

period before it will detect motion. When
first turned on, wait 1

1

/

2

minutes.

RANGE

10 5 1 TEST

ON-TIME

Bottom of Sensor

Avoid aiming the control at:

• Objects that change temperature rapidly, such

as

heating vents and air conditioners. These

heat sources could cause false triggering.

• Areas where

pets or traffic may trigger the

control.

Nearby large, light-colored objects reflecting
light may trigger the shut-off feature. Do not point

MIN

MAX

180°

Loosen the clamp screw

in the sensor ball joint and
gently rotate the sensor.

Walk through the cover-

age area noting where
you are when the lights
turn on (also, the LED will
flash several times when
motion is detected). Move
the sensor head up, down,
or sideways to change the
coverage area.

Keep the

sensor at least 1" (2.5 cm)
away from the lamps.

Adjust the RANGE as

needed. RANGE set too
high may increase false
triggering.

Secure the sensor head
by tightening the clamp
screw.
Do not overtighten the screw.

Set the amount of TIME you want the lights to stay

on after motion is detected (1, 5, or 10 minutes).

WARNING: Risk of fire. Do not aim the lamps

at a combustible surface within 3 ft. (1 m).

SPECIFICATIONS

Range . . . . . . . . . . . . . . Up to 70 ft. (21 m) [varies with

surrounding temperature].

Sensing Angle . . . . . . . . Up to 180°
Electrical Load . . . . . . . . Up to 500 Watt (4.2A) Maximum

Incandescent [Up to 250 Watt
maximum each lamp holder.]

Power Requirements . . . 120 VAC, 60 Hz
Operating Modes . . . . . . TEST, AUTO and MANUAL

MODE

Time Delay . . . . . . . . . . 1 , 5, 10 minutes
Range . . . . . . . . . . . . . . Adjustable
HeathCo LLC reserves the right to discontinue prod-
ucts and to change specifications at any time without
incurring any obligation to incorporate new features in
products previously sold.

Turn the RANGE control to the mid position and

the ON-TIME control to the TEST position.

Clamp
Screw

Ball
Joint

Aim Sensor

Down for Short

Coverage

Aim Sensor

Higher for Long

Coverage