Glossary duty cycle, Specifications – Husky D29616 User Manual

Page 8

Advertising
background image

8- ENG

D29616

GLOSSARY

DUTY CYCLE

Become familiar with these terms before operating the unit.
CFM: Cubic feet per minute.
SCFM: Standard cubic feet per minute; a unit of measure of air delivery.
PSIG: Pounds per square inch gauge; a unit of measure of pressure.
Code Certification: Products that bear one or more of the following marks:
UL, CUL, ETL, CETL, have been evaluated by OSHA certified independent
safety laboratories and meet the applicable Underwriters Laboratories
Standards for Safety.
Cut-In Pressure: While the motor is off, air tank pressure drops as you
continue to use your accessory. When the tank pressure drops to a certain low
level the motor will restart automatically. The low pressure at which the motor
automatically restarts is called “cut-in” pressure.
Cut-Out Pressure: When an air compressor is turned on and begins to run,
air pressure in the air tank begins to build. It builds to a certain high pressure
before the motor automatically shuts off - protecting your air tank from
pressure higher than its capacity. The high pressure at which the motor shuts
off is called “cut-out” pressure.
Branch Circuit: Circuit carrying electricity from electrical panel to outlet.

SPECIFICATIONS

Model No.

Y6020

Maximum Kinetic HP

5.2

Running HP

1.5

Bore

1.875"

Stroke

1.25"

Voltage-Single Phase

120V

Minimum Branch Circuit Requirement

15 amps

Fuse Type

Time Delay

Air Tank Capacity - (gallon)

25

Approximate Cut-in Pressure

120 PSIG

Approximate Cut-out Pressure

150 PSIG

SCFM @ 40 PSIG

4.9

SCFM @ 90 PSIG

3.5

This air compressor pump is capable of running continuously. However, to
prolong the life of your air compressor, it is recommended that a 50%-75%
average duty cycle be maintained; that is, the air compressor pump should not
run more than 30-45 minutes in any given hour.