68-0063—3

4

L8104A,B,C,D

SPECIFICATIONS

ACCESSORIES:

L8104A:

4074ENP Potentiometer Assembly: 199075A Poten-

tiometer: Clockwise turn increases temperature,
two 18 in. [46 cm] leadwires with 1/4 in. quick
connects. Washer and nut.

4074ENS Potentiometer Assembly: 199053A Potenti-

ometer: Counterclockwise turn increases tempera-
ture, two 18 in. (46 cm) leadwires with one bare wire
and one 1/4 in. quick connect. Washer and nut.

198800A One-Shot Sensor Assembly (nonrecyclying):

189

°F (87°C) cutoff temperature. 11 in. (28 cm)

sensor and ECO leadwires. Sensor leadwire is 1/4
in. quick connect. ECO leadwire is stripped.

198800B One-Shot Sensor Assembly (non recycling):

200

°F (93°C) cutoff temperature. 11 in. (28 cm)

sensor and ECO leadwires. Sensor leadwire is 1/4
in. quick connect. ECO leadwire is stripped.

198799B Sensor Assembly: 42 in. (107 cm) 150

°C

(302

°F) leadwires with 1/4 in. quick connects.

L8104B:

198799A Sensor Assembly: 42 in. (107 cm) 125

°C

(257

°F) leadwires with 1/4 in. quick connects.

198799B Sensor Assembly: 42 in. (107 cm) 150

°C

(302

°F) leadwires with 1/4 in. quick connects.

198799C Sensor Assembly: 42 in. (107 cm) 105

°C

(221

°F) leadwires with 1/4 in. quick connects.

198799D Sensor Assembly: 42 in. (107 cm) 105

°C

(221

°F) leadwires with 1/4 in. quick connects.

200636A Sensor Assembly: 180

° F to 201°F (83°C to

94

°C) cutoff temperature. 22 in. (56 cm) 150°C

(302

°F) leadwires.

200636B Sensor Assembly: 180

°F to 201°F (83°C to

94

°C) cutoff temperature. 22 in. (56 cm) 150°C

(302

°F) leadwires.

200636C Sensor Assembly: 180

°F to 201°F (83°C to

94

°C) cutoff temperature. 22 in. (56 cm) 150°C

(302

°F) leadwires.

200650A Potentiometer: Clockwise turn increases tem-

perature. 8 in. (20 cm) leadwires with two 1/4 in.
quick connects.

Fig. 3—Approximate dimensions in in. (mm) of L8104C,D Electronic Control Module.

140

120

160

180

100

SEN-1

SEN-2

LOWER

UPPER

24V

COM.

LOAD

19/32

(15)

1/2

(13)

1-1/8 (29)

9/32

(7)

1 (25)

4-23/64

(111)

2-61/64

(75)

(TWO)

.170 DIA. (FOUR)

1/4 IN.TAB
TERMINALS

LOCKOUT
INDICATOR
LIGHT

3/16 IN. TAB
TERMINALS

1/4

(6)

(TWO)

1/4

(6)

(TWO)

1 (25)

1-61/64 (50)

2-7/16 (62)

1

1

1

MODELS WITH REMOTE POTENTIOMETER HAVE TWO
1/4 IN. TAB TERMINALS IN PLACE OF THE POTENTIOMETER.

M414

PV

ECO

ECO

VALVE

U1

K1

C1

K2

PUSH BUTTON RESET