Honeywell XG1000 User Manual

Page 2

Advertising
background image

I

2

ROUTER

(NOT INCLUDED)

INTERNET

DSL/CABLE MODEM

(NOT INCLUDED)

2

1

3

2

4

LAN

LAN

WAN

XG1OOO CONTROLLER

INSTALLATION CHECKLIST ///

XG1000 Controller and a

Honeywell Bridge

6160 Alpha panel as a debugging tool

Confirm address 22 is open and configured as a keypad device.

Please note that if 22 is already is use, the existing keypad will need to be
moved to a different address

Remote account username and password

INSTALL & VALIDATE XG1000 CONTROLLER ///

1. Locate the customer’s external internet connection and the in-home router. Find one unused
LAN RJ-45 port on the router. Then, use an Ethernet cable to connect the LAN RJ45 port on
the XG1000 Controller to the unused LAN RJ45 port on the router.

2. Connect XG1000 Controller to power and verify the following:

The XG1000

‘X’ power LED is lighted

BLUE

If the power LED is not lighted, please re-check all power connections
(see

Troubleshooting Section

)

The XG1000 LAN/Link LED is lighted

GREEN

If the LAN/Link LED does not light check the Ethernet connection and/or
try using a different Ethernet cable (see

Troubleshooting Section

)

3. Wait up to 3 minutes for the XG1000 Controller to initialize.

4. Check and confirm LED marked

‘REM’ is solid GREEN (REM LED is the health indicator

for remote access).

POWER

INDICA

TOR

LAN LINK

REMOTE

CONNECTIVITY

ACT

ST

AT

REM

DEV

ACT

LINK

LAN

CONTROL TERMINAL STRIP

AUX.

4

AUX.

+

5

DATA

IN

6

DATA

OUT

7

HONEYWELL

BRIDGE

SAFEWATCH PRO 3000

BRIDGE RED WIRE

BRIDGE YEL WIRE

BRIDGE GRN WIRE

TO KEYPAD YEL WIRE

TO KEYPAD GRN WIRE

TO KEYPAD BLK WIRE

TO KEYPAD RED WIRE

BRIDGE BLK WIRE

HONEYWELL BRIDGE INSTALLATION PROCEDURE ///

1. Connect the

Honeywell Bridge to the Honeywell Panel (or the keypad if possible)

The Bridge connects just like an additional keypad (SafeWatch Pro 3000 terminals noted).

Please power down the Honeywell Panel prior to beginning this process:

Black wire to Pin 4

Red wire to Pin 5

Green wire to Pin 6

Yellow wire to Pin 7

NOTE: The existing keypad will remain connected. Mount the Bridge device near the alarm panel away
from large metal objects. If necessary, you can extend the length of the wire using four conductor cable
and wire nuts. For best results the bridge device should be mounted as high as possible, preferably at
least 6 feet above the floor.

2. Re-connect power to the Honeywell Panel.

3. The LED on the

Honeywell Bridge should light up and display

RED

– If the LED does not light up,

the Bridge is not receiving power, please check all connections (see

Troubleshooting Section

).

If the LED changes from solid GREEN to solid RED within the first 60 seconds after applying power,
and remains solid RED, the Controller and the Bridge may be having difficulty communicating.
Please perform the

Range Test described in the

Troubleshooting Section

of this manual.

4. Go to existing alarm keypad. Disarm the alarm system, establish access to alarm system
via the

“Installer Code”

(may need to re-power unit and use

‘#*’ to set an installer code).

5. Connect a 6160 ALPHA KEYPAD if existing keypad is not alpha. From the keypad enable
the keypad address 22 in the alarm panel for use by the

Honeywell Bridge (for the SafeWatch

Pro 3000, enter

‘[ 1, 0 ]’ in location ‘*195’).

Advertising