Prior to turning the gas supply on, be sure the gas valve knob
on the gas control valve is in the OFF position.

Upon initial installation, and after moving the unit, the piping and

fittings should be checked for gas leaks. A simple checking

method is to turn on the gas and brush all connections with a soap

solution. If bubbles occur, it indicates escaping gas.

In this event,

the piping connection must be redone.




To avoid fire or explosion, never use a lighted
match or open flame to test for gas leaks.
Ignited gas could result in severe personal
injury and/or property damage.

2-8. GAS PRESSURE REGULATOR

The gas pressure regulator on the gas control valve is

SETTING

factory set as follows:


• Natural: 3.5 inches water column (0.87 mbar).

• Propane 10.0 inches water column (2.49 mbar).

The gas pressure regulator has been set by Henny

Penny and is not to be adjusted by the user.


• 120 V, 50/60 Hz., 1 PH, 12 A

• 230 V, 50 Hz., 1 PH, 6 A

The 120 V gas open fryer requires a 3 wire grounded (earthed)

service and is supplied with a grounded cord and plug. Any 230

volt plug used on the 230 volt unit must conform to all local,

state, and national codes.

To avoid electrical shock, this appliance must be

equipped with an external circuit breaker which

incorporates a 3mm disconnection in all ungrounded

(unearthed) conductors. The main power switch on this

appliance does not disconnect all line conductors.

1210

2-6

2-7. GAS LEAK TEST

2-9. ELECTRICAL REQUIREMENTS