Troubleshooting wiring connections – Heath Zenith 6108 User Manual

Page 6

Advertising
background image

6

598-1233-02

Test again. Go

to 2 or 3.

If light does not

turn on:

1.

If light turns

on with remote

switch in either

position:

3.

Wait for the unit to warm up (up to 1

minute). If the remote switch can turn

the lights on, it’s OK. Otherwise:

Exchange* Control’s

Black ⇔ Brown wires. Remove the

tape. Go to the next page.

2.

If light turns on in

only one position

of remote switch:

Exchange* Control’s

Red ⇔ Brown wires.

TROUBLESHOOTING WIRING CONNECTIONS

Test again. Go

to 1 or 3.

3. For test purposes, use a small, phillips screw-

driver to turn the TIME control to the TEST
(5 second) position (see Figure 6). Turn the
power back on at the circuit breaker.

4. Verify the switch has power. The bottom LED

will be lit.

5. Allow the sensor to stabilize (about 1 minute).

The sensor is ready to detect motion.

6. Push the ON/OFF button. The lights and mo-

tion sensor will turn on. The lights will remain
on as long as the sensor detects motion or the
ON/OFF button is pushed again. The lights
will turn off 5 seconds after motion stops.

TESTING

1. Remove the decorative cover plate (secured by

two small screws).

2. Pinch control panel cover at the indicated points

as shown in Figure 5. Pull to remove cover.

Decorative
Cover
Plate

Figure 5 - Removing Control Panel Cover

Pinch Here

Pinch Here

Figure 6 - Control Panel

T I M E

5

25

10

15

1

Test

WARNING: Turn power off at the circuit breaker before rewiring.

Exchange* Control’s

Red ⇔ Black wires.