Honeywell Mark III User Manual

Page 55

Advertising
background image

HONEYWELL Aerospace Electronic Systems

Page 55

Use or disclosure of information on this page is subject to the restrictions on the title page of this document.

Category A2, Pin Injection Tests (DO-160C Section 22.5.1)
Waveform 3 (DO-160D Section 22, Figure 22-4), Voc/Isc = 250V/10A, and Frequency = 1 Mhz + 20%.
Waveform 4 (DO-160D Section 22, Figure 22-5), Voc/Isc = 125V/25A.

Category E3, Cable Bundle Tests, Cable Induction (DO-160C Section 22.5.2)
Waveform 1 (DO-160D Section 22, Figure 22-2), Vl/It = 300V/600A.
Waveform 3 (DO-160D Section 22, Figure 22-4), Vt/Il = 600V/120A, and Frequency = 1 Mhz and 10 Mhz

Lightning Direct Effects (DO-160D Section 23.0)
Category X, Not Applicable

Icing (DO-160D Section 24.0)
Category X, Not Applicable

ESD (DO-160D Section 25.0)
Category A, Equipment Installed, Repaired, or operated in an Aerospace Environment

DO-160D Marking (DO-160D Appendix A)
[(A2)(F2)W]BBB[(UF)(SCLMY)]EXXXXXZ[EBZ]A[EZ]Z[RRR]M[A2E3]XXA

5.5 Power Requirements

The MARK III is able to accept either 115 Vac 400 Hertz and/or 28 Vdc input power. The unit is designed
so that if both sources are inadvertently connected, the MARK III or aircraft will not be damaged.

The following subsections specify the unit’s power requirements and operating conditions:

5.5.1 115 Vac Input Power Requirements

The MARK III meets DO-160D Section 16.0 category E requirements. It has the following operating voltage
and frequency specifications and input power requirements:

Operating Voltage

Operating Frequency

Power Consumption

Nominal

115 Vrms

Minimum

97 Vrms

Maximum

134 Vrms

Nominal

400 Hertz

Minimum

320 Hertz

Maximum

480 Hertz

Nominal

50 Watts

Maximum

100 Watts

5.5.2 28 Vdc Input Power Requirements