4

598-1157-05

TEST AND ADJUSTMENT

Turn on the circuit breaker and light switch.

Loosen the clamp screw in the

sensor ball joint and gently
rotate the sensor.

Walk through the coverage

area noting where you are
when the lights turn on (also,
the LED will flash several times
when motion is detected). Move
the sensor head up, down, or
sideways to change the cover-
age area.

Keep the sensor at

least 1" (2.5 cm) away from
the lamps.

Adjust the RANGE as needed.

RANGE set too high may
increase false triggering.

Secure the sensor head by
tightening the clamp screw.

Do not overtighten the screw.

Set the amount of TIME you want the lights to stay

on after motion is detected (1, 5, or 10 minutes).

SPECIFICATIONS

Range . . . . . . . . . . . . Up to 70 ft. (21 m) [varies with

surrounding temperature].

Sensing Angle . . . . . . Up to 180°
Electrical Load . . . . . . Up to 240 Watt Maximum Tung-

sten [Up to 120 Watt maximum
each lamp holder.]

Power Requirements . 120 VAC, 60 Hz
Operating Modes . . . . TEST, AUTO and MANUAL

MODE

Time Delay . . . . . . . . 1, 5, 10 minutes
Range . . . . . . . . . . . . Adjustable
HeathCo LLC reserves the right to discontinue prod-
ucts and to change specifications at any time without
incurring any obligation to incorporate new features
in products previously sold.

NOTE: Sensor has a 1

1

/

2

minute warm up period

before it will detect motion. When first turned
on, wait 1

1

/

2

minutes.

Bottom of Sensor

Avoid aiming the control at:

• Objects that change temperature rapidly, such as

heating vents and air conditioners. These heat
sources could cause false triggering.

• Areas where

pets or traffic may trigger the control.

Nearby large, light-colored objects reflecting light
may trigger the shut-off feature. Do not point other
lights at the sensor.

70 ft.

(21 m)

8 ft.

(2.4 m)

Clamp
Screw

Ball
Joint

Aim Sensor

Down for Short

Coverage

Aim Sensor

Higher for Long

Coverage

Least Sensitive

Most Sensitive

WARNING: Risk of fire. Do not aim the lamps

at a combustible surface within 3 ft. (1 m).

Maximum Range

Maximum

Coverage Angle

RANGE

10 5 1 TEST

ON-TIME

MAX

MIN

RANGE

ON-TIME

10 5 1 TEST

MINUTES

MIN

MAX

NOTE: Meets the ENERGY STAR

®

guidelines when used

with 120 W Max bulbs.

Turn the RANGE control to the mid position (halfway

between MIN and MAX) and the ON-TIME control
to the TEST position.

Motion

Motion

180°

Sensor

NOTE: If fixture is mounted higher than 8 ft. (2.4 m), aiming
the sensor down will reduce coverage distance.
The detector is less sensitive to motion directly towards it.