Make sure the extension cord is properly
7.
wired and in good electrical condition.
Always replace a damaged extension
cord or have it repaired by a qualified
electrician before using it.
Protect the extension cords from sharp
8.
objects, excessive heat, and damp or
wet areas.
reCOMMended MiniMuM wire gauge
FOr eXtensiOn COrds*
(120/240 VOlt)
naMeplate
aMperes
(at full load)
eXtensiOn COrd
length
25’ 50’ 75’ 100’ 150’
0 – 2.0
18
18
18
18
16
2.1 – 3.4
18
18
18
16
14
3.5 – 5.0
18
18
16
14
12
5.1 – 7.0
18
16
14
12
12
7.1 – 12.0
18
14
12
10
-
12.1 – 16.0
14
12
10
-
-
16.1 – 20.0
12
10
-
-
-
table a
* based on limiting the line volt‑
age drop to five volts at 150% of
the rated amperes.