COMPONENT

All measurements are taken per ARI 1200 - 2002 specifications.

E

NERGY

D

ATA

OWZA

Defrost Controls

Model

Defrosts

Per Day

Electric Defrost

6

Timed Off Defrost

7

Hot Gas Defrost

Reverse Air Defrost

Fail-Safe

(min)

Termination

Temp (°F)

Fail-Safe

(min)

Termination

Temp (°F)

Fail-Safe

(min)

Termination

Temp (°F)

Fail-Safe

(min)

Termination

Temp (°F)

OWZA - 8'

2

50

46

50

46

- - -

8

- - -

- - -

- - -

6 Low temperature defrost

7 Medium temperature defrost

8 "- - -" not an option on this case model.

Guidelines & Control Settings

Model

24hr Energy

Usage

(kWh)

Suction Pressure

@ Case Outlet

(psig)

Superheat Set

Point @ bulb

(Fo)

Discharge

Air

(Fo)

Return

Air

(Fo)

Discharge

Air Velocity

5

(FPM)

OWZA - 8’

(med temp)

9.3

60.8

6 - 8

25.7

33.3

200

OWZA - 8’

(low temp)

13.5

16.3

6 - 8

-17

3

200

5 Average discharge air velocity at peak of defrost.

System Requirements

Model

Volts

Phase

Hz

Plug

Style

Cord

Length

OWZA - 8'

230

1

60

L14-30P

10'

1 For export cases, a NEMA L6-30 electrical plug is used.

Condensing Unit Data (2 units/case)

Model

Volts

Phase

Frequency

(Hz)

HP

RLA

2

(amps)

LRA

3

(amps)

Refrig.

Condenser

Fans

Lbs. of

Refrig.

Amps

4

Watts

OWZA - 8’

(med temp)

208-230

1

60

3/4

7.7

37.0

R404A

1.4

70

5

OWZA - 8’

(low temp)

208-230

1

60

1-1/2

15.4

74.0

R404A

2.8

140

10

2 RLA = Running Load Amps

3 LRA = Locked Rotor Amps

4 Amps shown are included in RLA rating.

2