For technical questions, please call 1-800-444-3353.

Item 67697

SAFET

y

M

AINTENAN

c

E

PARTS LIST

SETUP

Grounding

TO PREVENT ELEcTRIc SHOcK AND DEATH

FROM INcORREcT GROUNDING WIRE cONNEcTION:

check with a qualified electrician if you are in doubt as to whether the outlet is properly grounded.

Do not modify the power cord plug provided with any motor used with this compressor Pump.

Never remove the grounding prong from the plug. Do not use the motor if the power cord or plug is damaged.

If damaged, have it repaired by a service facility before use. If the plug will not fit the outlet, have a proper

outlet installed by a qualified electrician.

Symbology

PSI

Pounds per square inch of pressure

cFM

Cubic Feet per Minute flow

ScFM

Cubic Feet per Minute flow

at standard conditions

NPT

National pipe thread, tapered

NPS

National pipe thread, straight

Double Insulated

Canadian Standards Association

Underwriters Laboratories, Inc.

V

Volts

~

Alternating Current

A

Amperes

Specifications

Type

Single Stage Twin Cylinder; Oil Lubricated

Required HP

3 HP motor

Rated Air Pressure 145 PSI
Maximum Speed

1050 RPM

Air Outlet

3/4" –16 UNF

Air Delivery

@ 1050 RPM

11 SCFM @ 40 PSI

10 SCFM @ 90 PSI

Lubrication

Splash Type with Oil Level Window

Oil Type

SAE 30W non-detergent Air Compressor Oil

(Sold separately)

Pump Pulley

12-1/2" diameter with single V-groove

Belt Type

A 1397

Mounting Hole

Pattern

5-23/32" x 7-5/16" (center-to-center)

Four 3/8" diameter holes

Recommended

Mounting Bolts

5/16" diameter, grade 5 or better

Overall Dimensions 12-5/8" L x 10-3/4" W x 14-1/4" H
Sound Level

89 dB @ 1m