Finish Mounting

Align the JourneyMan

®

cover plate, gasket,

and the mounting bracket hole. Secure with
M5 x 0.8 x 40 mm mounting screw supplied.

Push the rubber plug firmly into place.

If not installed on a weatherproof box, caulk

between the cover plate and mounting sur-

face with silicone weather sealant.

Adjust the lamp holders by loosening the

thumb screws but do not rotate the lamp hold-
ers more than 180° from the factory setting.
When screwing in the floodlamps, do not
overtighten.

To avoid water damage and
electrical shock, keep lamp
holders aimed below horizontal.

Specifications

Range . . . . . . . . . . . . . 70 feet (21.0 m); 100

feet (30.5 m) with Range
Boost. Varies with sur-
rounding temperature.

Sensing Angle . . . . . . . Up to 270° (Adjustable)

Fixture Load . . . . . . . . Up to 300 Watts Maximum

Tungsten Incandescent
[Up to 150 Watts maxi-
mum each lamp holder.]

Sensor Load Capacity . Up to 1000 Watts (8.3

amps), Maximum Tung-
sten Incandescent

Power Requirements . . 120 VAC, 60 Hz

Operating Modes . . . . . TEST, AUTO, and MAN-

UAL OVERRIDE

Time Delay . . . . . . . . . 1, 5, 20 minutes

HeathCo LLC reserves the right to discontinue
products and to change specifications at any time
without incurring any obligation to incorporate
new features in products previously sold.