HP StorageWorks 7100ux User Manual

Page 55

Advertising
background image

Troubleshooting

55

HP StorageWorks 3800ux/7100ux Optical Jukebox User’s Guide

RESERVED

displays when a disk is

inserted into the mailslot

The

SECURE MS

configuration is set.

Disks cannot be loaded. To change this

setting, see “

Setting an operating

configuration

” on page 41.

MAILSLOT EMPTY

displays when a

disk is inserted into the mailslot

Remove and then replace the disk

fully into the mailslot.

If the same error reappears, then the

mailslot sensors are not detecting a

disk and may be defective. Contact

your service representative.

DEST NOW FULL

displays when a disk

is inserted into the mailslot

The jukebox moved a disk into the slot

you chose before your load command

executed.

Press CANCEL, select another slot

for the disk, and then reattempt a

load.

Initiate an

INIT

ELEM

STATUS

test (see

Internal tests

” on page 47).

TRANSPORT FULL

displays when a

disk is inserted into the mailslot

The disk transport mechanism

already contains a disk. Refer to

your host and application software

documentation for recovery

procedures.

Attempt an

EMPTY

PICKER

test

(see “

Internal tests

” on page 47).

If unsuccessful, contact your support

representative.

MAILSLOT SENSOR

displays when a

disk is inserted into the mailslot

Remove and then re-insert the disk.

If unsuccessful, the jukebox mailslot

sensors may have failed. Contact

your service representative.

EJECT ERROR

displays when a disk

eject is attempted

Press CANCEL. Attempt to eject the

disk again.

If the light bar on the control panel

is amber, cycle power to the jukebox

and try to eject the disk again when

READY

displays.

If there is no disk in the mailslot and

this error message repeats, contact

your service representative.

Table 9: Troubleshooting installation (Continued)

Problem

Solution

Advertising
This manual is related to the following products: