Honeywell CHRONOTHERM T8602C User Manual

T8602c chronotherm, Iv deluxe programmable thermostats, Mercury notice

Advertising
background image

® U.S. Registered Trademark
Copyright © 2003 Honeywell •

• All Rights Reserved

INSTALLATION INSTRUCTIONS

69-1670

T8602C Chronotherm

®

IV

Deluxe Programmable

Thermostats

APPLICATION

The T8602 Chronotherm

®

IV Deluxe Programmable Thermostat provides electronic control of 24 Vac single-stage

heating and cooling systems or 750 mV heating system. Refer to Table 1 for a general description of the thermostat. All
T8602 thermostats are powered by batteries.

Table 1. Description of T8602 Thermostats.

MERCURY NOTICE

If this control is replacing a control that contains
mercury in a sealed tube, do not place your old
control in the trash. Dispose of properly.

Contact your local waste management authority
for instructions regarding recycling and the
proper disposal of the old control.

INSTALLATION

When Installing this Product...

1. Read these instructions carefully. Failure to follow

the instructions can damage the product or cause
a hazardous condition.

2. Check the ratings given in the instructions and on

the product to make sure the product is suitable for
your application.

3. Installer must be a trained, experienced service

technician.

4. After completing installation, use these instructions

to check out the product operation.

Location

Install the thermostat about 5 ft (1.5m) above the floor in
an area with good air circulation at average temperature.
See Fig. 1.

Do not install the thermostat where it can be affected by:
— drafts, or dead spots behind doors and in corners.
— hot or cold air from ducts.
— radiant heat from sun or appliances.
— concealed pipes and chimneys.
— unheated (uncooled) areas such as an outside wall

behind the thermostat.

Wallplate Installation

The thermostat can be mounted horizontally on the wall
or on a 2 in. x 4 in. (50.8 mm x 101.6 mm) wiring box.
Position wallplate horizontally on the wall or on a
2 in. x 4 in. (50.8 mm x 101.6 mm) wiring box.

T8602

System

Changeover

System Selection

Fan

Selection

Comments

C

Heat-Cool

Manual

Heat-Off-Cool

On-Auto

System and fan selections are made on
keyboard.