1. Select a location on a flat wall with structurally sound wood

and from 10 to 25 feet (3 to 7.6 m) from the ground. The wood
should be at least one inch thick to safely secure the fixture.

2. Using the mounting template as a guide, mark the 3 mounting

holes. We suggest drilling 3/16" (4.8 mm) pilot holes for the
lag screws.

3. Install the two bottom lag screws first. Screw in the lag screws

so that there is about 3/8" (9.5 mm) of space under the head.

4. Place the fixture on these two screws and install the top lag screw.

Tighten the top lag screw first, then tighten the remaining lag
screws.

5. Secure your outdoor cable or flexible conduit to the cover plate

with a fitting in accordance with the National Electrical Code
(Canadian Electrical Code in Canada).

6. Thread the black and white fixture wires through the hole in the

cover plate as shown.

7. Connect the fixture wires to the service wires (black to black

and white to white).

8. This fixture

must be connected to ground. Secure the service

ground wire under the head of the green ground screw.

9. Install the cover plate. Secure with the two screws and nuts

provided.

10. Install the reflector/lens assembly. Secure with the two screws

and washers provided.

11. Screw in the 175 watt mercury vapor type H39 lamp provided.
12. Loosen the screw in the center of the photocontrol socket two

turns. Twist the socket so that the arrow points north.

Note: There

is a stop to prevent the socket from turning all the way around.
If you have trouble turning the socket, try turning it the other
direction. Retighten the screw in the center of the socket.

13. Align the photocontrol with the socket (it will only plug-in one way).

Plug it in and twist clockwise until it stops. If photocontrol is already
installed, turn clockwise to ensure that it is locked in place.

Ground Screw

Photocontrol

Lens/Reflector

Assembly

Fixture Wires Thru

This Hole

Cover Plate

See your Canadian Tire retailer for warranty information.

No Service Parts Available for this Product

Mercury Vapor Dusk to Dawn

175W Security Light for

Canadian Tire

Installation Instructions

READ ALL INSTRUCTIONS CAREFULLY BEFORE BEGINNING INSTALLATION.

NOTE: All wiring must be run in accordance with the National Electrical Code (Canadian Electrical Code in Canada) through

conduit or another acceptable means. Contact a qualified electrician if there is any question as to the suitability of
the system.

Model SL-5650

WARNING: Turn power off at the fuse or circuit

breaker.

Lamp in Fixture Contains Mercury. Dispose According
to Local, State, or Federal Laws.

To test operation during daylight, cover the photocontrol with a small box. Turn on the power. Not all photocontrols are alike. Some may
have a time delay of a few minutes, others will turn on as soon as power is applied. The light will take up to ten minutes to reach full
brightness. Uncover the photocontrol and your unit will operate automatically—on at dusk, off at dawn.