Output sequence editor, Require output sequence – HandHeld Entertainment 4600r User Manual

Page 67

Advertising
background image

3 - 19

9999

code length that must match for Code 93, 9999 = all lengths

43

start character match for Code 93, 43h = “C”

FF

termination string for third code

To program the previous example using specific lengths, you would have to
count any programmed prefixes, suffixes, or formatted characters as part of the
length. If you use the example on

page 3-18

, but assume a <CR> suffix and

specific code lengths, you would use the following command line:

SEQBLK62001241FF6A001342FF69001243FF

The breakdown of the command line is shown below:

SEQBLK sequence editor start command
62

code identifier for Code 39

0012

A - Code 39 sample length (11) plus CR suffix (1) = 12

41

start character match for Code 39, 41h = “A”

FF

termination string for first code

6A

code identifier for Code 128

0013

B - Code 128 sample length (12) plus CR suffix (1) = 13

42

start character match for Code 128, 42h = “B”

FF

termination string for second code

69

code identifier for Code 93

0012

C - Code 93 sample length (11) plus CR suffix (1) = 12

43

start character match for Code 93, 43h = “C”

FF

termination string for third code

Output Sequence Editor

Require Output Sequence

When an output sequence is

Required

, all output data must conform to an

edited sequence or the imager will not transmit the output data to the host
device. When it’s

On/Not Required

, the imager will attempt to get the output

data to conform to an edited sequence, but if it cannot, the imager transmits all
output data to the host device as is.

Enter Sequence

Default Sequence