Emergency Depressurization

If it is necessary to quickly depressurize the Compressor, turn the Power Switch OFF.

Then, pull on the ring on the Safety Valve to quickly release stored air pressure.

Automatic Shut off System

Reset

Button

Figure I: Reset Button

1. If the Compressor automatically shuts off

before reaching its normal cutoff pressure:
a. Shut off all tools.
b. Wait until the Compressor cools down

(about 10 minutes);

c. If the unit does not start up again on its own,

press the Reset Button to start the compressor;

d. Resume operation.

2. Possible causes of repeated automatic

shut off of the compressor are:
a. Using an extension cord that is too long or narrow;
b. An air leak or open hose causing the compressor

to cycle too often and build up heat.

3. Correct any issues before further use to

avoid damage to the compressor.