Service

20

310622L

For Sanitary Ball Check pumps: remove ball gasket
(242) and ball (541). Remove lower clamp (132b),
seat (233), and gasket (240). Clean all parts and
inspect for wear or damage. Replace parts as
needed.

For Flapper Check pumps: remove gasket (240).
Remove middle clamp (232) and housing (252).
Remove middle gasket (250), flapper retainer (253),
and flapper valve (251). Remove lower clamp
(132b), lower flapper housing (248), and gasket
(240). Clean all parts and inspect for wear or dam-
age. Replace parts as needed.

6.

Disassemble the outlet manifold. Remove clamps
(130), tee (339), gasket (129), and elbow (128).
Clean all parts and inspect for wear or damage.
Replace parts as needed.

F

IG

. 14

TI8769a

128

129*

339*

233

*240

132b

132a

*242

130

*541

331*

Sanitary Ball Check Assembly

F

IG

. 15

TI8770a

129*

130

Flapper Check Assembly

132a

240*

252

232*

251
248

240*

132b

250

253