Henny Penny DCW-2 User Manual

Page 16

Advertising
background image

SECTION 4. TROUBLESHOOTING

4-1. TROUBLESHOOTING GUIDE


PROBLEM

CAUSE CORRECTION

Product not holding

z

Doors are not kept closed


z

Product held too long

z

Temperature too low

z

Radiant heat too low

z

Light bulbs out

z

Keep doors closed when holding possible

z

Only hold product for recommended times

z

Turn to higher setting

z

Turn to higher setting

z

Replace as required, per light Bulbs and

Glass Panels section

Doors are fogging

z

Doors left open too much allowing

doors to cool and cause condensation

z

Radiant heat not high enough

z

Temperature too high

z

Keep doors closed when possible


z

Turn to higher setting

z

See recommended settings and temperature

Lights will not turn
on

z

Defective fuse

z

Replace 15 amp fuse

Not all lights on

z

Faulty light bulbs

z

Replace with recommended bulb, per Light

Bulbs and Glass Panels section


More detailed troubleshooting information is available in the Technical Manual, available at

www.hennypenny.com, or 800-417-8405 or 937-456-8405.














12