Installation – Harman Stove Company Harman Gas 929BV User Manual

Page 4

Advertising
background image



In.addition.to.these.clearances,.adequate.accessibil-

ity.clearance.for.servicing.and.proper.operation.must.be.

maintained.

Do.not.in.any.way.obstruct.the.combustion.air.inlets.

that.are.located.under.the.heater.

If.this.appliance.is.installed.directly.on.carpeting,.tile.

or other combustible material other than wood flooring the

appliance.shall.be.installed.on.a.metal.or.wood.panel.ex-

tending.at.least.the.full.width.and.depth.of.the.appliance.

INSTALLATION

CleaRanCes

The.following.clearances.to.combustibles.must.be.

observed:

Unit.to.left.sidewall.

9".. (230.mm)

Unit.to.right.sidewall.

9".. (230.mm)

Unit.corner.to.walls.

4".. (100.mm)

Rear.of.unit.to.back.wall.

3".. (75.mm)

(measured.from.rear.of.draft.hood.to.wall)

Unit.to.alcove.ceiling.

18".. (460.mm)

Maximum.alcove.depth.

14".. (355.mm)

Due to high temperatures, the Clarity Vented Gas

Heater should be located out of traffic and away

from furniture and draperies.

Children and adults should be alerted to the haz-

ards of high surface temperatures and should stay

away to avoid burns or clothing ignition.

Young children should be carefully supervised

when they are in the same room as the Clarity

Vented Gas Heater.

Clothing or other flammable materials should

not be placed on or near the Clarity Vented Gas

Heater.

Sidewall Clearance

Clearance to Back wall

Clearance from corner of unit to walls

Clearance to alcove ceiling

Maximum alcove depth

Advertising