SECTION V -

SERVICING & REPLACEMENT OF PARTS


WARNING / CAUTION


Before servicing or replacing any part make sure to turn the power supply switch to the OFF position.


SURFACE TEMPERATURE HIGH LIMIT CUT-OFF

1. Disconnect power from unit.
2. Remove access cover.
3. Disconnect the four (4) 14 gauge wires or three (3) 14 gauge wires and a jumper, as required.




Control Wires High-Limit Cut-Off Switch






Manual Reset Control Wires







Temperature Controller






4. Disconnect the high-limit cut-off switch from the temperature controller by pulling the cut-

off switch up and away from temperature controller.

5. Replace control and install new high limit switch by performing above steps in reverse order.