Electrical parts – Heat Controller COMFORT-CINE REG-243A User Manual

Page 15

Advertising
background image

Service Manual 16

Disassembly

6. Fan

1. Remove the cabinet. (Refer to section 2)

2. Remove the brace and shroud cover.

(Refer to section 4)

3. Remove the side cover with 2 screws.(See Fig. 23)

4. Remove the 5 or 6 screws which fasten the condenser.

5. Move the condenser sideways carefully.

6. Remove the clamp which secures the fan.

7. Remove the fan. (See Fig. 23)

8. Re-install the components by referring to the removal

procedure, above.

7. Shroud

1. Remove the fan. (Refer to section 6)

2. Remove the 2 screws which fasten the shroud.

3. Remove the shroud. (See Fig. 24)

4. Re-install the component by referring to the removal

procedure, above.

8. Motor

1. Remove the cabinet. (Refer to section 2)

2. Remove the cover control and disconnect a wire hous-

ing in control box. (Refer to section 3)

3. Remove the blower. (Refer to section 5)

4. Remove the fan. (Refer to section 6)

5. Remove the 4 screws which fasten the motor. (See Fig.

25)

6. Remove the motor.

7. Re-install the components by referring to the removal

procedure, above.

9. Compressor

1. Remove the cabinet. (Refer to section 2)

2. Discharge the refrigerant system using FreonTM

Recovery System.
If there is no valve to attach the recovery system,
install one (such as a watco a-1) before venting the
Freon

TM

. Leave the valve in place after servicing the

system.

3. Disconnect the 3 leads from the compressor.

4. After purging the unit completely, unbraze the suction

and discharge tubes at the compressor connections.

5. Remove the 3 nuts and the 3 washers which fasten the

compressor. (See Fig. 26)

6. Remove the compressor.

7. Re-instill the components by referring to the removal

procedure, above.

Electrical parts

Figure 23

Figure 24

Figure 25

Figure 26

Advertising